Related Experiment Video
Updated: Jun 10, 2026

A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Biomechanical stress distribution on fixation screws used in bilateral sagittal split ramus osteotomy: assessment of
Behnam Bohluli1, Mohammad Hosein Kalantar Motamedi, Pedram Bohluli
1Department of Oral and Maxillofacial Surgery, Buali Hospital, Azad University of Medical Sciences, Tehran, Iran.
Purpose:
The aim of this study was to assess the biomechanical stress tolerance of screws used in 9 fixation methods after bilateral sagittal split ramus osteotomy to determine which configuration leads to lesser force load on the cortical bone at fixation points.
Materials And Methods:
A 3-dimensional computerized model of a human mandible with posterior teeth was generated. The bilateral sagittal split ramus osteotomy was virtually performed on this model. The separated model was assembled with 9 fixation methods: single screw, 2 screws one behind the other, 2 screws one below the other, 3 screws in an L configuration, 3 screws in an inverted backward L configuration, miniplate with 2 screws, miniplate with 4 screws, 2 parallel plates (upper + lower border), and square miniplate with 4 screws. Then, 75-, 135-, and 600-N vertical loads were applied on the posterior teeth of these models. The stress distribution on the screw sites on the buccal cortex was measured by the finite element method.
Results:
In this model all the fixation methods withstood forces between 75 and 135 N. However, the single-screw and the 2-hole miniplate models showed that the stress distributions in the configurations were intolerable when 600 N of posterior force was applied. The results of this study indicated that the inverted backward L configuration with 3 bicortical screws was the most stable.
Conclusion:
Although this study indicated that the inverted backward L configuration with 3 bicortical screws was the most stable pattern, most of the patterns had adequate stability for clinical applications (mean, 125 N).