Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
Beam characteristics and radiation output of a kilovoltage cone-beam CT
George X Ding1, Charles W Coffey
1Department of Radiation Oncology, School of Medicine, Vanderbilt-Ingram Cancer Center, Vanderbilt University, B-902, TVC, 1301 Medical Center Drive, Nashville, TN 37232-5671, USA. george.ding@vanderbilt.edu
Abstract:
This study presents beam characteristics of five recently available x-ray beams produced by an on-board imager (OBI 1.4) for acquiring kilovoltage cone-beam computed tomography (kV-CBCT) and investigates suitable methods for the beam radiation output determination resulting from an image acquisition. Both are essential for commissioning an x-ray beam in a radiotherapy treatment planning system. The BEAM/DOSXYZnrc Monte Carlo codes were used in the investigation. The simulated beam data were benchmarked against measurements. Three different commercially available plastic phantom materials are investigated as liquid water substitutes in the beam radiation output determination. Ionization chambers are used for the measurements. Five kV-CBCT beam characteristics including photon fluence, average beam energy and photon spectra are generated from Monte Carlo simulations. The Monte Carlo calculated dose profiles are validated by measurements. The fluence of kV-CBCT beams is strongly dependent on the geometry of added filters as well as X and Y beam collimations. The potential errors of determining the beam output of a kV-CBCT beam in Solid Water and PMMA phantoms may approach 8% and 20%, respectively, for use in a conventional treatment planning system, whereas using the Plastic Water low-energy range (PW-LR) phantom results in errors within 2%. The Monte Carlo simulation is essential in providing the parameters of an x-ray beam which are needed for the commissioning of a kV-CBCT beam in a radiotherapy treatment planning system. The PW-LR phantom is a suitable liquid water substitute in the beam output determination resulting from a kV-CBCT acquisition.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
X-ray Imaging