Related Experiment Video
Updated: Jun 10, 2026

Introduction of Intracapsular Rotary-cut Procedures (IRCP): A Modified Hysteromyomectomy Procedures Facilitating Fertility Preservation
Published on: January 17, 2019
Hysteroscopic removal of intrauterine contraceptive device embedded within submucous myoma
Jian-Hua Wang1, Li-quan Wang, Xu-Jun Shang-Guan
1Department of Family Planning, Women's Hospital, Zhejiang University, Hangzhou, China.
Abstract:
We report that an intrauterine contraceptive device (IUCD) embedded within intrauterine tumour (submucous myoma) in a postmenopausal woman was misdiagnosed, definitively diagnosed and successfully removed with hysteroscopic resection. Hysteroscopy and hysteroscopic resection of the submucous myoma with IUCD should be reserved as a minimally invasive, safe and reliable treatment method, and can avoid a laparotomy and hysterotomy. This is believed to be the first reported case of such an occurrence.