Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Manipulation and Localized Deposition of Particle Groups with Modulated Electric Fields.

Micromachines·2020
Same author

Comparison of Renal Artery <i>vs</i> Renal Artery-Vein Clamping During Partial Nephrectomy: A System Review and Meta-Analysis.

Journal of endourology·2020
Same author

Identification of Potential Prognostic Long Non-Coding RNA Biomarkers for Predicting Recurrence in Patients with Cervical Cancer.

Cancer management and research·2020
Same author

Enhanced Thermoelectric and Mechanical Performance in n-Type Yb-Filled Skutterudites through Aluminum Alloying.

ACS applied materials & interfaces·2020
Same author

Tracking and Predicting Depressive Symptoms of Adolescents Using Smartphone-Based Self-Reports, Parental Evaluations, and Passive Phone Sensor Data: Development and Usability Study.

JMIR mental health·2020
Same author

Thermal damage of tungsten-armored plasma-facing components under high heat flux loads.

Scientific reports·2020

Related Experiment Video

Updated: Jun 10, 2026

Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
12:54

Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo

Published on: October 2, 2021

Wavefront aberration measurements and corrections through thick tissue using fluorescent microsphere reference

Oscar Azucena1, Justin Crest, Jian Cao

  • 1Jack Baskin School of Engineering, Univ of California, Santa Cruz, 1156 High St, Santa Cruz, CA 95064, USA. azucena@soe.ucsc.edu

Optics Express
|August 20, 2010
PubMed
Summary

This study introduces a technique to improve image clarity when looking through thick biological samples. By placing tiny glowing beads inside a fruit fly embryo, researchers can measure and fix light distortions caused by the tissue. A specialized mirror adjusts in real-time to sharpen the final picture, significantly boosting image quality for deeper biological observation.

Keywords:
adaptive opticsDrosophila embryoShack-Hartmann sensordeformable mirrorStrehl ratio

Frequently Asked Questions

More Related Videos

Conducting Multiple Imaging Modes with One Fluorescence Microscope
08:32

Conducting Multiple Imaging Modes with One Fluorescence Microscope

Published on: October 28, 2018

Using Light Sheet Fluorescence Microscopy to Image Zebrafish Eye Development
13:01

Using Light Sheet Fluorescence Microscopy to Image Zebrafish Eye Development

Published on: April 10, 2016

Related Experiment Videos

Last Updated: Jun 10, 2026

Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
12:54

Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo

Published on: October 2, 2021

Conducting Multiple Imaging Modes with One Fluorescence Microscope
08:32

Conducting Multiple Imaging Modes with One Fluorescence Microscope

Published on: October 28, 2018

Using Light Sheet Fluorescence Microscopy to Image Zebrafish Eye Development
13:01

Using Light Sheet Fluorescence Microscopy to Image Zebrafish Eye Development

Published on: April 10, 2016

Area of Science:

  • Optical physics and wavefront aberration correction research
  • Biomedical imaging within microscopy technology

Background:

Imaging deep inside biological specimens remains a significant challenge due to light scattering and distortion. Prior research has shown that tissue heterogeneity disrupts light paths, leading to blurred visual data. No prior work had resolved how to effectively compensate for these complex distortions in real-time. That uncertainty drove the development of adaptive optics for biological applications. Scientists often struggle to obtain clear images when light passes through dense layers. This gap motivated the search for reliable reference points within opaque samples. Existing methods frequently lack the precision needed for thick, living structures. Researchers needed a way to map these aberrations accurately to restore image fidelity.

Purpose Of The Study:

The aim of this study is to introduce a direct method for measuring and correcting light distortions in thick biological samples. Researchers sought to overcome the image degradation caused by light passing through dense tissue. They specifically addressed the challenge of imaging through a Drosophila embryo. The team aimed to implement a system that uses fluorescent microspheres as artificial guide-stars. This approach intends to provide a reliable reference for wavefront sensing. They wanted to demonstrate that real-time corrections could restore image clarity. The motivation stems from the need for higher resolution in deep-tissue microscopy. By applying inverse patterns to a deformable mirror, they hoped to achieve significant improvements in optical performance.

Main Methods:

The review approach involved utilizing a Shack-Hartmann sensor to quantify phase distortions. Researchers seeded Drosophila embryos with fluorescent beads to act as point sources. They integrated a micro-electro-mechanical deformable mirror into the optical path. This device applied inverse phase patterns to compensate for tissue-induced errors. The team executed these corrections in ten-millisecond increments. They evaluated the performance by comparing images before and after the adaptive process. The experimental design focused on light transmission through 100 micrometers of biological material. This setup allowed for the systematic assessment of image quality improvements.

Main Results:

Key findings from the literature indicate a substantial increase in the Strehl ratio following correction. The average improvement reached two times across the tested samples. Under specific conditions, the researchers observed enhancements up to ten times when imaging through 100 micrometers of tissue. The data reveal an isoplanatic half-width of approximately 19 micrometers. This measurement establishes a corrected field of view with a 38-micrometer diameter. These results confirm the effectiveness of using artificial guide-stars for deep-tissue observation. The study provides quantitative evidence for the utility of rapid mirror adjustments. The findings highlight the potential for achieving higher resolution in thick specimens.

Conclusions:

The authors demonstrate that their technique successfully mitigates light distortion through dense biological material. This synthesis suggests that using internal reference points provides a viable pathway for deep-tissue imaging. The findings imply that real-time adjustments significantly enhance the clarity of microscopic structures. Their work confirms that deformable mirrors can effectively counteract tissue-induced errors. The study indicates that the corrected field of view remains limited by the isoplanatic patch size. These implications highlight the trade-off between correction depth and spatial coverage. The researchers conclude that their method offers a robust solution for high-resolution microscopy. Future applications may benefit from the improved Strehl ratios observed in these experiments.

The researchers utilize a Shack-Hartmann sensor to quantify light distortion. By applying an inverse phase pattern to a deformable mirror, they counteract the errors. This process occurs in ten-millisecond intervals, allowing for rapid correction of the light path as it travels through the sample.

Fluorescent microspheres serve as artificial guide-stars within the specimen. These tiny beads provide the necessary reference light source to map how the tissue bends and scatters incoming rays, enabling the system to calculate the required adjustments for the mirror.

A Shack-Hartmann sensor is necessary to capture the wavefront error directly. Without this specific tool, the system could not quantify the precise phase shifts induced by the Drosophila embryo, preventing the calculation of the inverse pattern needed for the deformable mirror.

The deformable mirror acts as the primary corrective component. It receives the calculated inverse wavefront data to physically reshape the reflected light, effectively canceling out the aberrations introduced by the thick tissue during the imaging process.

The team measured an isoplanatic half-width of approximately 19 micrometers. This value defines the spatial extent of the correction, resulting in a total corrected field of view measuring 38 micrometers in diameter around the chosen guide-star.

The authors propose that their method improves the Strehl ratio by an average of two times. In optimal conditions, they observed improvements as high as ten times when imaging through 100 micrometers of tissue, demonstrating the efficacy of their approach.