Related Experiment Video
Updated: Oct 3, 2026

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Normal fluctuation of physiologic cardiovascular variables during anesthesia and the phenomenon of "smoothing"
1Department of Anesthesiology, College of Medicine, Ohio State University, Columbus 43210.
Abstract:
With the advent of automated anesthesia record keeping devices, concern has arisen that "abnormal" values will appear in the record and possibly lead to medicolegal compromise. A retrospective review of automated records from a series of anesthesia cases was undertaken to determine if abnormal values do occur, how frequent they are, and whether they cause problems. A total of 14,826 (4,942 each) noninvasive heart rate, systolic, and diastolic blood pressure readings from 118 case printouts generated by a Diatek Arkive Patient Information Management System (63 cases) or a Datascope Datatrac record keeper (55 cases) were recorded. The study sample covered a broad range of surgical operations, anesthetic procedures, and patient ages and medical histories. During these 118 anesthetics, the majority of readings of all three variables fell within normal ranges (defined for this study as 80 to 180 and 50 to 110 mm Hg for systolic and diastolic blood pressures, respectively, and 60 to 140 beats/min for heart rate). During the anesthetics, 3.6% of the systolic pressure readings, 13.25% of the diastolic readings, and 4.25% of the heart rate readings were recorded outside these ranges. No serious intraoperative or postoperative anesthesia complications were associated with these out-of-range readings, nor would they be expected in a sample of this size, since serious anesthetic complications are rare. This preliminary observation of one person's experience may help address the concern associated with allowing high and low blood pressure and heart rate readings to be automatically recorded "unsmoothed." In medicolegal situations, it should also begin to demonstrate that such fluctuations are neither uncommon nor abnormal, and that a true record of these readings should be neither a cause for concern nor an opportunity for medicolegal exploitation.
Related Concept Videos
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Regulation of the Cardiovascular System
The regulation of the cardiovascular system involves the autonomic nervous system (ANS), baroreceptors, and chemoreceptors, ensuring that heart rate and blood pressure are appropriately modulated in response to varying physiological demands.
The ANS comprises two main divisions: the sympathetic and parasympathetic nervous systems. The sympathetic nervous system enhances...
Cardiomyopathy VII: Pre and Post Operative Nursing Management