Related Experiment Video
Updated: Jun 10, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
[Analysis of the results and methods on proficiency testing of determination of Fe, Mn in drinking water]
Peiyao Tian1, Xinhua Xiang, Sujuan Zhao
1Center for Disease Prevention and Control, Beijing 100013, China.
Objective:
To analyse the results and methods on proficiency testing(PT) for determination of Fe, Mn in drinking water and to discuss the influencing factors. With a view to the laboratory for accurate determination of drinking water iron and manganese to provide technical support.
Methods:
180 labs from 30 provinces (cities), autonomous regions took part in the PT. Based on methods of PT, statistical analysis of the results, to find the causes of dissatisfactory results.
Results:
According to the results of the report for the first time, the PT showed that 85.56% labs presented satisfactory results of determination of Fe and 87.71% labs presented satisfactory results of determination of Mn. In addition to ICP/MS, it showed that 76.00%, 88.89%, 93.75% respectively presented satisfactory results of the methods of AAS, ICP-AES and chemical of determination of Fe. It showed that 79.23%, 94.29%, 72.73% respectively presented satisfactory results of the methods of chemical, AAS and ICP-AES of determination of Mn. The initial results of 37 labs had dissatisfactory. Results of statistics showed that iron, manganese at the same time [ZB] > or = 3 for the 11 labs.
Conclusion:
Most of the labs that took part in the PT have good competence in analyzing Fe, Mn. The main reasons of the dissatisfactory results were larger systematic errors, experimental blank, matrix interference and feeble control ability of the key point of the experiment.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
Related Concept Videos
Precipitation and Co-precipitation
Testing Water Quality
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...