The pressure profile test is more sensitive and specific than Palmer's test in predicting correct placement of the
Wai Yoong1, Shika Saxena, Monica Mittal
1Department of Obstetrics and Gynaecology, North Middlesex University Hospital, London N18 1QX, UK. wai.yoong@nmh.nhs.uk
Objectives:
Although the majority of laparoscopic complications result from improper Veress needle placement, the safety tests commonly used to determine correct placement are not always reliable. A prospective observational study (Canadian Task Force Classification II-2) was set up to determine the reliability of Palmer's and pressure profile tests in predicting the correct intraperitoneal placement of the Veress needle prior to insufflation.
Study Design:
One hundred consecutive women undergoing gynaecological laparoscopic surgery between September 2006 and June 2007 were recruited. The operating surgeons conducted Palmer's and pressure profile tests in all 100 cases and recorded the ease with which these tests were performed and whether or not they felt that the needle placement was correct. They were also asked to comment on the saline drop test and double click acoustic test if appropriate.
Results:
The overall sensitivity of Palmer's test was 0.92 while its specificity was 0.5. The overall sensitivity and specificity of the pressure profile test were 0.99 and 0.75, respectively, making this a more reliable test for predicting intraperitoneal placement of the Veress needle.
Conclusions:
The pressure profile test was a more reliable guide to confirming the correct placement of the Veress needle as a negative test is more likely to indicate failure to achieve intraperitoneal placement.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Assessment of the Abdomen III: Palpation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Pre-Procedural Guidelines for Assessing Blood Pressure
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...