Dynamic studies of nitrophenols adsorption on perfil in a fixed-bed column: application of single and two resistance
Zvezdelina Yaneva1, Bogdana Koumanova, Vera Meshko
1University of Chemical Technology and Metallurgy, 8 Kliment Ohridski Blvd, 1756 Sofia, Bulgaria.
Abstract:
The mechanism of 4-nitrophenol (4-NP) and 2,4-dinitrophenol (2,4-DNP) adsorption on perfil-natural mineral taken from Bulgarian deposits, in a fixed-bed column was investigated. The single component experiments were conducted at constant initial sorbate concentration, volumetric flow rate, temperature and pH. The effect of adsorbent bed depth (Z 1, 2, 3, 6 cm) and sorbate nature on the adsorption capacity, mass transfer parameters and mechanisms was studied. The equilibrium behaviour of the system 4-NP-perfil was described by Langmuir, Freundlich and Redlich-Peterson models. The single resistance Thomas model, including Reynolds-Richards and Walter solutions, and the two-resistance Arnold model were applied for mathematical modeling of the experimental data. The comparative analyses indicated that external mass transfer was the rate limiting mechanism during the initial adsorption stages, while intraparticle diffusion was dominant in the middle and high concentration ranges. The effect of axial dispersion on the dynamics of adsorption was evaluated.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Analyte Adsorption and Distribution
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Adsorption Isotherms I
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...