Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Influence of Earth's Curvature and Atmospheric Refraction on Leveling01:26

Influence of Earth's Curvature and Atmospheric Refraction on Leveling

During leveling, the Earth's curvature and atmospheric refraction introduce deviations in the line of sight from a true horizontal reference. When the line of sight is leveled, it remains perpendicular to the plumb line only at a single point. Beyond this, it deviates due to the Earth’s curvature, represented by the correction C. For a sight distance D, the deviation can be derived using the relationship:This relationship shows that the deviation increases quadratically with distance. Over a...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Investigation of LE-LIBS feasibility for detection of H, He, and O in high vacuum using geological samples.

Optics letters·2025
Same author

Fringe formation in multiaperture speckle shear interferometry.

Applied optics·2010
Same author

Multiple-beam lateral shear interferometry for optical testing.

Applied optics·2010
Same author

Modified double-wedge-plate shearing interferometer for collimation testing.

Applied optics·2010
Same author

Multiple-beam wedge-plate shear interferometer for collimation testing.

Applied optics·2010
Same author

Real-time image processing with a cat conjugator.

Applied optics·2010
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: Jun 9, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
10:39

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

Published on: October 11, 2016

Direct determination of focal length by using Talbot interferometry.

K V Sriram, M P Kothiyal, R S Sirohi

    Applied Optics
    |August 25, 2010
    PubMed
    Summary
    This summary is machine-generated.

    A novel Talbot interferometry technique simplifies measuring the focal length of lenses and concave surfaces. This method achieves high measurement accuracy, offering a straightforward approach for optical analysis.

    More Related Videos

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
    12:14

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry

    Published on: August 12, 2013

    Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy (iPALM)
    11:57

    Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy (iPALM)

    Published on: December 1, 2016

    Related Experiment Videos

    Last Updated: Jun 9, 2026

    Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
    10:39

    Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

    Published on: October 11, 2016

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
    12:14

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry

    Published on: August 12, 2013

    Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy (iPALM)
    11:57

    Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy (iPALM)

    Published on: December 1, 2016

    Area of Science:

    • Optics and optical engineering
    • Metrology and measurement science

    Background:

    • Accurate determination of focal length is crucial for optical system design and performance evaluation.
    • Existing methods for focal length measurement may involve complex setups or lower precision.

    Purpose of the Study:

    • To introduce a new, simple technique for determining the focal length of positive lenses and concave spherical surfaces.
    • To demonstrate the applicability and accuracy of Talbot interferometry for this measurement task.

    Main Methods:

    • Utilized Talbot interferometry, a well-established optical phenomenon.
    • Developed a simplified experimental setup for implementing the technique.

    Main Results:

    • Successfully applied the technique to measure the focal length of positive lenses.
    • Successfully applied the technique to measure the focal length of concave spherical surfaces.
    • Presented measurement results demonstrating high accuracy.

    Conclusions:

    • The described Talbot interferometry technique offers a simple and accurate method for focal length determination.
    • This technique provides a valuable tool for optical metrology and lens characterization.