Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Real-time three-dimensional speckle tracking echocardiography: a novel technique to quantify global left ventricular
Christophe Thebault1, Erwan Donal, Anne Bernard
1Cardiologie & INSERM, CIC-IT 804, Renes F-35000, France.
Aims:
left ventricular (LV) mechanical dyssynchrony (LVMD) has emerged as a therapeutic target using cardiac resynchronization therapy (CRT) in chronic heart failure patients. Current methods used to evaluate LVMD are technically challenging and do not assess all the components of LVMD simultaneously. We analysed real-time 3D speckle tracking (3DST) echocardiography as a novel method to assess LVMD.
Methods And Results:
three-dimensional ST was performed in 60 unselected patients (71 ± 9 years old; 39% with ischaemic cardiomyopathy) who were referred to optimize and to control of a CRT device; implanted according to current guidelines (9 added to be excluded from the protocol). Two standardized conditions [right ventricular (RV) versus an optimized biventricular (BiV) pacing modality] were tested. These two pacing modalities lead to two distinct electrical activation patterns. We sought to test the capability of 3DST to distinguish these two patterns. The LV ejection fraction was 24 ± 9 in the RV mode and 29 ± 10% in BiV. By 3DST, we measured global end-systolic LV deformation and dyssynchrony (standard deviation of the time to peak/16 LV-segment). The 3D radial strain increased from 13.8 ± 5.7 in the RV to 15.9 ± 6.5% in theBiV mode, and the dyssynchrony index decreased from 15.1 ± 5.0 to 11.8 ± 4.1%. 3D longitudinal strain increased from -6.9 ± 2.8 in the RV to -7.8 ± 3.2% in the BiV mode, and the dyssynchrony index decreased from 14.2 ± 4.8 to 11.5 ± 5.0% (P < 0.01 for all). The 3D area strain (AS) increased from -15.4 ± 6 in the RV to -18.3 ± 7.0% in the BiV mode, and the dyssynchrony index decreased from 12.2 ± 5.1 to 9.5 ± 4.5% (P < 0.001 for all).
Conclusion:
When image quality is optimal, 3DST might offer a new rapid method to quantify global LVMD in CRT candidates. In a comparison of the utility of various 3D strain measurements, the 3D AS appears to be closed to the ideal parameter that we are looking for.
More Related Videos
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...