Related Experiment Video
Updated: Jun 9, 2026

Non-invasive Optical Imaging of the Lymphatic Vasculature of a Mouse
Published on: March 8, 2013
[Diagnosis of peripheral lymph circulation disorders with contrast MR lymphangiography]
Ning-Fei Liu1, Qing Lu, Zhao-Hua Jiang
1Department of Plastic Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai 200011, China. liuningfei@126.com
Objective:
To evaluate anatomical and functional images of contrast MR lymphangiography in the diagnosis of limb lymphatic circulation disorders.
Methods:
30 patients with limb lymphedema were enrolled in the study. There were 27 patients of primary lymphedema and 3 of secondary lymphedema. Contrast enhanced lymphangiography was performed with 3.0 T MR Unit after intracutaneous injection of gadobenate dimeglumine into the interdigital webs of the dorsal foot and hand. The kinetics of enhanced lymph flow within the lymphatics were calculated using the formula: Speed (cm) = total length of visualized lymph vessel (cm)/ inspection time (minutes) and by comparing dynamic nodal enhancement and time-signal intensity curves between edematous and contralateral limbs. Morphological abnormalities of the lymphatic system were also evaluated.
Results:
Following injection of the contrast agent enhanced lymphatic channels were consistently visualized in all clinical lymphedematous limbs and five contralateral limbs of unilateral lymphedema cases. The speed of enhanced flow within the lymphatics of lymphedematous limbs ranged from 0.30 to 1.48 cm/min. The contrast enhancement in inguinal nodes of edematous limbs was significantly lower than that of contralateral limbs (P < 0.01). Dynamic measurement of contrast enhancement showed a remarkable lowering of peak time (P < 0.01) and peak enhancement (P < 0.01) and a delay in outflow in inguinal nodes of affected limbs compared with that of control limbs. Post-contrast MR imaging also depicted varied distribution patterns of lymphatics and abnormal lymph flow pathways within lymph nodes in the limbs with lymphatic circulation disorders.
Conclusions:
Contrast MR lymphangiography with gadobenate dimeglumine was able to visualize the precise anatomy of lymphatic vessels and lymph nodes in lymphedematous limbs. It also provided comprehensive information about the functional status of lymph flow transportation in lymphatics and lymph nodes.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
