The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland
Mohammed Najeeb Al Hallak1, Matt McCurdy, Nicolas Zouain
1University of North Dakota School of Medicine and Health Sciences, Fargo, N. Dak., USA.
Abstract:
(153)Sm-EDTMP is a radiopharmaceutical composed of EDTMP (ethylenediamine-tetramethylenephosphonate) and Samarium-153 [1]. (153)Sm-EDTMP has an affinity for skeletal tissue and concentrates in areas with increased bone turnover; thus, it is successfully used in relieving pain related to diffuse bone metastases [1]. The manufacturing process of (153)Sm-EDTMP leads to contamination with (154)Eu (Europium-154) [2]. A previous study only alluded to the retention of (154)Eu in the bones after receiving treatment with (153)Sm-EDTMP [2]. Activation of the alarm at security checkpoints after (153)Sm-EDTMP therapy has not been previously reported. Two out of 15 patients who received (153)Sm-EDTMP at Roger Maris Cancer Center (Fargo, N. Dak., USA) activated the radiation activity sensors while passing through checkpoints; one at a US airport and the other while crossing the American-Canadian border. We assume that the (154)Eu which remained in the patients' bones activated the sensors. METHODS: In order to investigate this hypothesis, we obtained the consent from 3 of our 15 patients who received (153)Sm-EDTMP within the previous 4 months to 2 years, including the patient who had activated the radiation alarm at the airport. The patients were scanned with a handheld detector and a gamma camera for energies from 511 keV to 1.3 MeV. RESULTS: All three patients exhibited identical spectral images, and further analysis showed that the observed spectra are the result of (154)Eu emissions. CONCLUSION: Depending on the detection thresholds and windows used by local and federal authorities, the remaining activity of (154)Eu retained in patients who received (153)Sm-EDTMP could be sufficient enough to increase the count rates above background levels and activate the sensors. At Roger Maris Cancer Center, patients are now informed of the potential consequences of (153)Sm-EDTMP therapy prior to initiating treatment. In addition, patients treated with (153)Sm-EDTMP at Roger Maris Cancer Center receive laminated cards stating the date and the dose of treatment, as well as a statement that the holder may activate the alarm at the security checkpoints.
More Related Videos
07:24Quantitative Atomic-Site Analysis of Functional Dopants/Point Defects in Crystalline Materials by Electron-Channeling-Enhanced Microanalysis
Published on: May 10, 2021
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
Atomic Emission Spectroscopy: Interference
Nuclear Transmutation
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab
Gas Chromatography: Types of Detectors-II