Methods of Sterilization I: Physical Methods01:29

Methods of Sterilization I: Physical Methods

As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods01:30

Methods of Sterilization II: Chemical Methods

In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature01:23

Physical Methods for Controlling Microbial Growth: Temperature

Heat is a widely used method to control microbial growth by targeting and denaturing cellular proteins, thereby killing or inactivating microbes. This method's effectiveness is quantified using parameters such as the thermal death point (TDP), thermal death time (TDT), and decimal reduction time (D value). TDP represents the lowest temperature at which all microorganisms in a liquid suspension are eliminated within 10 minutes, whereas TDT is the time necessary to achieve sterilization at a...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration01:26

Physical Methods for Controlling Microbial Growth: Radiation and Filtration

Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
Key Techniques in Microbiology01:19

Key Techniques in Microbiology

Aseptic techniques prevent contamination, ensure experimental accuracy, and protect researchers and microbial cultures. These techniques are essential in clinical, industrial, and research settings where sterility is required.Maintaining Sterility in Laboratory PracticesScientists maintain sterility by sterilizing tools with heat or chemicals, disinfecting work surfaces, and handling cultures in controlled environments. Working near an open flame or within a laminar flow hood reduces the risk...
Cleaning, Sterilization, and Disinfection01:30

Cleaning, Sterilization, and Disinfection

Cleaning, disinfection, and sterilization are the methods that help to break the infection chain and prevent disease.
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Search for Light Pseudoscalar Bosons, Pair-Produced in Higgs Boson Decays in the Four-Electron Final State in Proton-Proton Collisions at sqrt[s]=13  TeV.

Physical review letters·2026
Same author

First Evidence for Mixing-Induced CP Violation in B_{s}^{0}→J/ψϕ(1020) Decays in pp Collisions at sqrt[s]=13  TeV.

Physical review letters·2026
Same author

Observation of Suppressed Charged-Particle Production in Ultrarelativistic Oxygen-Oxygen Collisions.

Physical review letters·2026
Same author

Measurement of D^{0} Meson Photoproduction in Ultraperipheral Heavy Ion Collisions.

Physical review letters·2026
Same author

Observation of tWZ Production at the CMS Experiment.

Physical review letters·2026
Same author

First Exclusive Reconstruction of the B^{*+}, B^{*0}, and B_{s}^{*0} Mesons and Precise Measurement of Their Masses.

Physical review letters·2026
Same journal

Muscular pain during therapy with carbenoxolone (Biogastrone).

British medical journal·2016
Same journal

ACUTE INTESTINAL OBSTRUCTION DUE TO INTRA-ABDOMINAL CAUSES.

British medical journal·2014
Same journal

A CASE OF HAEMATIDROSIS.

British medical journal·2014
Same journal

Incidence of ulcer in haematemesis.

British medical journal·2011
Same journal

Pituitary hypothyroidism with impaired renal function.

British medical journal·2011
Same journal

The fenestration operation for otosclerosis.

British medical journal·2011
See all related articles

Related Experiment Video

Updated: Jun 9, 2026

A Flame-Free Method for Sterilizing C. elegans Picks, Spatulas, and Scalpels
04:30

A Flame-Free Method for Sterilizing C. elegans Picks, Spatulas, and Scalpels

Published on: March 4, 2022

A WEAK POINT IN STERILIZING METHODS

K Black

    British Medical Journal
    |August 27, 2010
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy
    10:03

    Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy

    Published on: November 30, 2017

    The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
    14:17

    The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military

    Published on: June 29, 2014

    Related Experiment Videos

    Last Updated: Jun 9, 2026

    A Flame-Free Method for Sterilizing C. elegans Picks, Spatulas, and Scalpels
    04:30

    A Flame-Free Method for Sterilizing C. elegans Picks, Spatulas, and Scalpels

    Published on: March 4, 2022

    Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy
    10:03

    Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy

    Published on: November 30, 2017

    The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
    14:17

    The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military

    Published on: June 29, 2014