Related Experiment Video
Updated: Jun 9, 2026

09:20
Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Congenital Complete Heart-block: The Effect of Atropine
British Medical Journal
|August 27, 2010
Abstract
No abstract available in PubMed .
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Bradyarrhythmias are cardiac rhythm disorders characterized by a slower-than-normal heart rate, typically defined as fewer than 60 beats per minute. Some of which are discussed here:Sinus BradycardiaSinus bradycardia presents a heart rate lower than 60 beats per minute, with a regular rhythm originating from the SA node. The ECG typically shows normal P waves preceding each QRS complex, a normal PR interval (0.12 to 0.20 seconds), and a normal QRS duration (0.06 to 0.10 seconds).First-Degree AV...
Nondepolarizing (Competitive) Neuromuscular Blockers: Pharmacological Actions
Nondepolarizing neuromuscular blockers prevent the membrane depolarization of muscle cells and inhibit muscle contraction. These are usually administered with anesthetics to achieve complete muscle relaxation. Upon administration, these drugs first block the small, rapidly contracting muscles of the face and hands, followed by the larger muscles of the trunk and the intercostal muscles. The diaphragm is the last muscle to be affected.
Although all competitive neuromuscular blockers are designed...
Although all competitive neuromuscular blockers are designed...
Conduction System of the Heart
Autorhythmicity is a term that refers to the heart's inherent ability to generate electrical signals and instigate muscle contractions. This self-regulating conduction system within the heart consists of two key components: the pacemaker cells and specialized conducting cells.
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
The cardiac conduction system produces and transmits electrical impulses that prompt myocardial contraction, ensuring efficient heart function. This intricate system ensures that the heart beats in a coordinated and efficient manner, beginning with the atria and then the ventricles. The conduction system optimizes cardiac output by maintaining this precise sequence, which is crucial for adequate blood circulation.
This system relies on the unique properties of nodal and Purkinje cells:...
This system relies on the unique properties of nodal and Purkinje cells:...
Antiarrhythmic Drugs: Class II Agents as β-Adrenergic Blockers
Adrenergic stimulation generally impacts cardiac rate and rhythm. Specifically, stimulation of the β-adrenoceptors triggers an increase in intracellular calcium ion influx and pacemaker currents, which may cause arrhythmias. Catecholamines like adrenaline also demonstrate β2-adrenoceptor-mediated hypokalemia, impacting cardiac action potential and disrupting the normal cardiac rhythm. Class II antiarrhythmic drugs are β-adrenoceptor antagonists or β-blockers, which indirectly block calcium...
Drugs Acting on Autonomic Ganglia: Blockers
Ganglionic blockers inhibit autonomic activity by blocking nicotinic receptors in the autonomic ganglia, suppressing impulse transmission. These blockers lack selectivity between sympathetic and parasympathetic ganglia and are ineffective as neuromuscular junction antagonists. They can be categorized into two groups:
