Related Experiment Video
Updated: Aug 12, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Volume calibration of various gasmeters using a modified Tissot spirometer
1Institute of Occupational Health, University of Dortmund, Federal Republic of Germany.
A modified Tissot spirometer was developed to calibrate indirect calorimetry devices like the Douglas bag, Kofranyi-Michaelis (KM), and Oxylog (OX). This new calibration tool ensures accurate volume measurements for energy expenditure research.
Area of Science:
- Physiology
- Biomedical Engineering
- Respiratory Measurement
Background:
- Indirect calorimetry methods, including the Douglas bag, Kofranyi-Michaelis (KM), and Oxylog (OX), are crucial for determining energy expenditure in various studies.
- Accurate volume measurement is essential for the reliability of these indirect calorimetry techniques.
Purpose of the Study:
- To develop and validate a modified Tissot spirometer for calibrating common indirect calorimetry apparatus.
- To ensure precise volume measurements across a range of physiological flow rates for improved accuracy in energy expenditure determination.
Main Methods:
- A modified Tissot spirometer was constructed with a novel buoyancy compensation system using a roller chain.
- The spirometer incorporates a vernier scale for lift measurement and a revolution counter for recording calibrated volumes up to 200 liters.
- Calibration procedures were established for the Kofranyi-Michaelis (KM) respirometer, wet gasmeters, and the Oxylog (OX).
Main Results:
- The modified Tissot spirometer successfully calibrated various indirect calorimetry devices.
- The Oxylog (OX) showed a minor inaccuracy of up to 2.0% between 20-70 L/min, increasing at higher flow rates.
- The developed spirometer facilitated repeatable calibrations under defined conditions.
Conclusions:
- The modified Tissot spirometer provides a reliable method for calibrating indirect calorimetry equipment.
- Accurate calibration is vital for enhancing the precision of energy expenditure measurements in physiological research.
- This tool supports consistent and dependable data acquisition for laboratory and field studies.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Gas Thermometers and the Kelvin Scale
Pressure Gauges
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...