Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Calibration of the 1-MHz Sonitron ultrasound system
Jonathan A Kopechek1, Hyunggun Kim, David D McPherson
1Department of Biomedical Engineering, Colleges of Engineering and Medicine, University of Cincinnati, Cincinnati, OH 45267-0586, USA. kopechja@uc.edu
Abstract:
Successful drug and gene delivery across cellular membranes can lead to improved therapeutic outcomes. Recent studies have suggested that sonoporation may enhance drug and gene delivery across cellular membranes. The enhancement may be a result of transient permeation of the membrane from cavitation or microstreaming effects of microbubbles exposed to ultrasound. Given limited acoustic pressure calibration and beam profile characterization of the Sonitron ultrasound systems in cellular bioeffects studies previously published, the objective of this work was to calibrate the acoustic output and explore the potential for standing waves in a cell-well plate. In this study, three 1-MHz transducers driven by Sonitron ultrasound systems, which have been used in a number of sonoporation studies, were calibrated. Transducers with 10-mm, 6-mm and 20-mm-diameter apertures (Sonitron 1000 and 2000, Rich-Mar, Inola, OK, USA) were calibrated using polyvinylidene fluoride (PVDF) needle hydrophones. Axial and transverse beam profiles were obtained, and the pressures were measured as a function of Sonitron intensity dial setting and duty cycle. The acoustic intensity was calculated and compared with the Sonitron intensity dial setting for duty cycles from 10-100%. Standing waves caused by reflections from the hydrophone holder were detected for each transducer. This observation may also have implications for in vitro sonoporation studies. Acoustic field characterization is an important first step in understanding the mechanisms of sonoporation and drug delivery across biomembranes.
More Related Videos
09:47A Methodological Protocol and Considerations for Transcranial Ultrasonic Stimulation in Exploratory Clinical Human Studies
Published on: December 12, 2025
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies II: Ultrasonography