Related Concept Videos

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
UV–Vis Spectroscopy: Beer–Lambert Law01:09

UV–Vis Spectroscopy: Beer–Lambert Law

The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...
Electron Paramagnetic Resonance (EPR) Spectroscopy: Organic Radicals01:17

Electron Paramagnetic Resonance (EPR) Spectroscopy: Organic Radicals

Ideally, an unpaired electron shows a single peak in the EPR spectrum due to the transition between the two spin energy states. However, coupling interactions can occur between the spins of the unpaired electron and any neighboring spin-active nuclei. This hyperfine coupling results in hyperfine splitting, where the EPR signal is split into multiplets. The signals split into 2nI + 1 peaks, where n is the number of equivalent nuclei and I is the nuclear spin. These splitting patterns provide...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A new simplified minimum data set better predicts outcomes for individuals admitted to intermediate care functional recovery units in catalonia.

The Journal of frailty & aging·2026
Same author

The Cryotop vitrification system is competent for the simultaneous cryopreservation of large numbers of pig in vitro-produced blastocysts.

Reproduction in domestic animals = Zuchthygiene·2024
Same author

Acute unilateral conjunctivitis as first manifestation of monkeypox viral infection after the 2023 vaccination campaign.

Journal francais d'ophtalmologie·2024
Same author

Air pollution and health prevention: A document of reflection.

Revista espanola de quimioterapia : publicacion oficial de la Sociedad Espanola de Quimioterapia·2022
Same author

N-(2-mercaptopropionyl)-glycine enhances in vitro pig embryo production and reduces oxidative stress.

Scientific reports·2020
Same author

The cytokine platelet factor 4 successfully replaces bovine serum albumin for the in vitro culture of porcine embryos.

Theriogenology·2019

Related Experiment Video

Updated: Jun 9, 2026

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
13:31

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

Published on: December 22, 2015

Spectral spread function of a double-pass parabolized Ebert monochromator.

M A Gil, G O Mattei

    Applied Optics
    |August 31, 2010
    PubMed
    Summary

    This study examines how residual coma and slit width affect spectral spread in a double-pass Ebert monochromator, providing insights for improved spectral resolution in optical instruments.

    Area of Science:

    • Optics and Spectroscopy
    • Instrumental Science

    Background:

    • Ebert monochromators are crucial for spectral analysis.
    • Understanding factors affecting spectral spread is key for instrument optimization.

    Purpose of the Study:

    • To investigate the impact of residual coma on spectral spread function.
    • To determine the influence of intermediate slit width on spectral performance.

    Main Methods:

    • Utilized a double-pass parabolized Ebert monochromator.
    • Analyzed spectral spread function under varying coma and slit width conditions.

    Main Results:

    • Residual coma was found to broaden the spectral spread function.
    • Intermediate slit width significantly altered spectral resolution and bandpass.

    More Related Videos

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
    07:55

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis

    Published on: September 22, 2017

    Hyperspectral Imaging as a Tool to Study Optical Anisotropy in Lanthanide-Based Molecular Single Crystals
    07:24

    Hyperspectral Imaging as a Tool to Study Optical Anisotropy in Lanthanide-Based Molecular Single Crystals

    Published on: April 14, 2020

    Related Experiment Videos

    Last Updated: Jun 9, 2026

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
    13:31

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

    Published on: December 22, 2015

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
    07:55

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis

    Published on: September 22, 2017

    Hyperspectral Imaging as a Tool to Study Optical Anisotropy in Lanthanide-Based Molecular Single Crystals
    07:24

    Hyperspectral Imaging as a Tool to Study Optical Anisotropy in Lanthanide-Based Molecular Single Crystals

    Published on: April 14, 2020

    Conclusions:

    • Optimizing slit width and minimizing residual coma are essential for enhancing monochromator spectral accuracy.
    • Findings guide the design of high-resolution spectroscopic instruments.