UV-B Robertson-Berger meter characterization and field calibration
Applied Optics
|August 31, 2010
Summary
The Robertson-Berger meter (RB meter) calibration was validated using theoretical modeling and spectral radiometer measurements. This study provides a precise conversion factor for solar UV-B radiation monitoring.
Area of Science:
- Atmospheric science
- Radiometry
- Solar radiation physics
Background:
- The New Zealand Meteorological Service has utilized Robertson-Berger meters (RB meters) for solar UV-B radiation monitoring over the last decade.
- Analysis of the instrument's radiometric properties confirms agreement with established Berger standards.
- Previous studies have not fully detailed the theoretical response of RB meters, particularly concerning cosine response.
Purpose of the Study:
- To present a comprehensive theoretical model of the Robertson-Berger meter's response, incorporating its cosine response.
- To validate this theoretical model using field measurements from both RB meters and a spectral radiometer.
- To derive an accurate calibration for the RB meter based on validated theoretical and experimental data.
Main Methods:
- Developed a detailed theoretical treatment of the Robertson-Berger meter's response, accounting for imperfect cosine response.
- Collected field data using both a Robertson-Berger meter and a double monochromator spectral radiometer under cloud-free conditions.
- Modeled the downward radiation field as direct solar and isotropic diffuse components to validate the theoretical model and derive calibration.
Main Results:
- The theoretical model for the RB meter's response, including cosine response, was validated through field measurements.
- A precise calibration was derived, establishing a conversion factor for the RB meter.
- A RB meter count was found to equate to 0.25 +/- 0.02 Jm(-2) for 300-nm radiation at vertical incidence.
Conclusions:
- The theoretical model accurately describes the Robertson-Berger meter's performance.
- The derived calibration provides a reliable method for quantifying solar UV-B radiation using RB meters.
- This research enhances the accuracy of UV-B radiation measurements for environmental and climate studies.
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
UV–Vis Spectroscopy: Beer–Lambert Law
The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...
Instrument Calibration
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
UV–Vis Spectrometers
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Measurement: Standard Units
Every measurement provides three kinds of information: the size or magnitude of the measurement (a number), a standard of comparison for the measurement (a unit), and an indication of the uncertainty of the measurement. While the number and unit are explicitly represented when a quantity is written, the uncertainty is an aspect of the errors in the measurement results.
Voltammetry: Factors Affecting Measurements
A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...