Related Experiment Video
Updated: Jun 9, 2026

Engineering Antiviral Agents via Surface Plasmon Resonance
Published on: June 14, 2022
Removal of viruscide agents by using styrenic resins
I Bartolozzi1, R Solaro, G Mari
1Department of Chemistry and Industrial Chemistry, University of Pisa - Italy.
Abstract:
Strong and weak anionic polystyrene/divinylbenzene ion exchange resins were investigated both as iodophores and as iodine/iodide ion removal agents in blood disinfection applications. Resin-iodine complexes were prepared, but there was no significant iodine release observed in either distilled water or isotonic saline solution. However, all ion-exchange resin were able to remove almost quantitatively both iodine and iodide ions from water solutions. Cross-linked styrene/divinylbenzene resins are excellent polyaromatic viruscide adsorbents, although their hydrophobicity is responsible for poor wettability in physiologi-cal fluids. Surface modification with hydrophilic reagents appeared a promising strategy to overcome this drawback. A Merrifield-type chloromethylated resin and a highly cross-linked mesoporous resin (Lewatit 1064) with a large surface area and content of unreacted vinyl groups were selected as starting materials. The Merrifield resin was modified by the reaction of the pendant chloromethyl groups with triethyleneglycol, tetraethyleneglycol and â -cyclodextrin. The conversion of Lewatit double bonds into hydrophilic moieties was attempted by the radical grafting of N-vinyl-2-pyrrolidinone (NVP), maleic anhydride (MAn), 2-hydroxyethyl methacrylate, acrylamide (AAm) and different poly(ethyleneglycol) (PEG) methacrylates. The addition of 2-mer-captoethanol (2ME) and epoxidation were also investigated. The modified Merrifield resins demonstrated very low efficiency in acridine viruscide uptake, in spite of the large increase in both wettability and water uptake. On the other hand, all modified Lewatit samples removed rapidly and almost quantitatively the viruscide from aqueous solutions, although only a few samples resulted in being very hydrophilic. In all cases, hydrophilicity and viruscide adsorbing capacity were maintained after heating at 180 degrees C to simulate pyrogen elimination.
Related Concept Videos
Chemical Agents for Microbial Control
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Antiviral Nucleoside Inhibitors
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...

