Related Experiment Video
Updated: Jun 9, 2026

Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Computer-aided detection of lung cancer on chest radiographs: effect on observer performance
Bartjan de Hoop1, Diederik W De Boo, Hester A Gietema
1Department of Radiology and Image Sciences Institute, University Medical Center, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands. b.j.dehoop@umcutrecht.nl
Purpose:
To assess how computer-aided detection (CAD) affects reader performance in detecting early lung cancer on chest radiographs.
Materials And Methods:
In this ethics committee-approved study, 46 individuals with 49 computed tomographically (CT)-detected and histologically proved lung cancers and 65 patients without nodules at CT were retrospectively included. All subjects participated in a lung cancer screening trial. Chest radiographs were obtained within 2 months after screening CT. Four radiology residents and two experienced radiologists were asked to identify and localize potential cancers on the chest radiographs, first without and subsequently with the use of CAD software. A figure of merit was calculated by using free-response receiver operating characteristic analysis.
Results:
Tumor diameter ranged from 5.1 to 50.7 mm (median, 11.8 mm). Fifty-one percent (22 of 49) of lesions were subtle and detected by two or fewer readers. Stand-alone CAD sensitivity was 61%, with an average of 2.4 false-positive annotations per chest radiograph. Average sensitivity was 63% for radiologists at 0.23 false-positive annotations per chest radiograph and 49% for residents at 0.45 false-positive annotations per chest radiograph. Figure of merit did not change significantly for any of the observers after using CAD. CAD marked between five and 16 cancers that were initially missed by the readers. These correctly CAD-depicted lesions were rejected by radiologists in 92% of cases and by residents in 77% of cases.
Conclusion:
The sensitivity of CAD in identifying lung cancers depicted with CT screening was similar to that of experienced radiologists. However, CAD did not improve cancer detection because, especially for subtle lesions, observers were unable to sufficiently differentiate true-positive from false-positive annotations.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...