The different photoplethysmographic patterns can help to distinguish patients with primary and sclerodermic Raynaud
Edoardo Rosato1, Carmelina Rossi, Federica Borghese
1Department of Clinical Medicine, Clinical Immunology Unit-Scleroderma Center, Sapienza University of Rome, Rome, Italy.
Introduction:
The aim of this study is to investigate pulsatility of digital arteries of hands by means of photoplethysmography (PPG) in patients with primary Raynaud phenomenon (PRP) and systemic sclerosis (SSc) and to compare the results with those obtained in healthy controls.
Methods:
One hundred five patients with SSc, 96 patients with PRP and 85 healthy controls were recruited in this study. Nailfold videocapillaroscopy and PPG were performed in healthy controls and patients. In patients with SSc, the capillaroscopic pattern was classified as early, active and late group pattern. A baseline PPG was recorded simultaneously in all 10 fingers of the hands. The photoplethysmographic curves were evaluated for morphology and amplitude of sphygmic wave.
Results:
In healthy controls group, PPG shows the presence of photoplethysmographic homogeneous pattern and high mean value of sphygmic wave amplitude. In PRP group, PPG demonstrates homogeneous photoplethysmographic pattern and low mean value of sphygmic wave amplitude. Finally, in the SSc group, photoplethysmographic pattern is dyshomogeneous, and the mean value of sphygmic wave amplitude is intermediate between the other 2 groups. The PPG findings are different in the 3 capillaroscopic groups of patients with SSc and 2 subsets of disease.
Conclusion:
PPG represents a technique noninvasive to evaluate simultaneously in all 10 fingers of hands digital arteries pulsatility. PPG improves the evaluation of vascular damage in patients with primary and sclerodermic RP.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Special considerations while measuring pulse
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...