Preparation and characterization of phosphatidylcholine-coated zirconia-magnesia stationary phase for artificial membrane chromatography
Related Experiment Video
Updated: Jun 9, 2026

Electrophoretic Crystallization of Ultrathin High-performance Metal-organic Framework Membranes
Published on: August 16, 2018
Weinong Zhang1, Zhixiong Hu, Yuqi Feng
1Department of Food Science, Wuhan Polytechnic University, Wuhan, PR China. zhangweinong@163.com
Abstract:
Immobilized artificial membrane chromatography stationary phase was prepared by coating soybean phosphatidylcholine (PC) on zirconia-magnesia micro-particles. The stability and chromatographic properties were investigated and compared with the PC-coated silica chromatography stationary phase prepared by the same method. PC-coated zirconia-magnesia chromatography stationary phase was more stable than the silica especially on resisting organic solvents. Hydrophobic action was the main factor for the retention of analyte on the new artificial membrane chromatography stationary phase, and electrostatic interaction had some contribution to retention. In addition, the special interaction between analyte and matrix affected retention greatly. Basic solutes were appropriate to be analyzed on PC-coated zirconia-magnesia stationary phase and acidic solutes were appropriate to be done on the silica one. Hence, the two different matrices artificial membrane stationary phases were perfectly complementary.
More Related Videos
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
07:32Preparation and Characterization of Individual and Multi-drug Loaded Physically Entrapped Polymeric Micelles
Published on: August 28, 2015
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Detergent Purification of Membrane Proteins
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...