Related Experiment Video
Updated: Jun 9, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Beat-to-beat three-dimensional ECG variability predicts ventricular arrhythmia in ICD recipients
Larisa G Tereshchenko1, Lichy Han, Alan Cheng
1Division of Cardiology, Department of Medicine, Johns Hopkins Hospital, Baltimore, Maryland, USA. lteresh1@jhmi.edu
Background:
Methodological difficulties associated with QT measurements prompt the search for new electrocardiographic markers of repolarization heterogeneity.
Objective:
We hypothesized that beat-to-beat 3-dimensional vectorcardiogram variability predicts ventricular arrhythmia (VA) in patients with structural heart disease, left ventricular systolic dysfunction, and implanted implantable cardioverter-defibrillators (ICDs).
Methods:
Baseline orthogonal electrocardiograms were recorded in 414 patients with structural heart disease (mean age 59.4 ± 12.0; 280 white [68%] and 134 black [32%]) at rest before implantation of ICD for primary prevention of sudden cardiac death. R and T peaks of 30 consecutive sinus beats were plotted in 3 dimensions to form an R peaks cloud and a T peaks cloud. The volume of the peaks cloud was calculated as the volume within the convex hull. Patients were followed up for at least 6 months; sustained VA with appropriate ICD therapies served as an end point.
Results:
During a mean follow-up time of 18.4 ± 12.5 months, 61 of the 414 patients (14.73% or 9.6% per person-year of follow-up) experienced sustained VA with appropriate ICD therapies: 41 of them were white and 20 were black. In the multivariate Cox model that included inducibility of VA and use of beta-blockers, the highest tertile of T/R peaks cloud volume ratio significantly predicted VA (hazard ratio 1.68, 95% confidence interval 1.01 to 2.80; P = .046) in all patients. T peaks cloud volume and T/R peaks cloud volume ratio were significantly smaller in black subjects (median 0.09 [interquartile range 0.04 to 0.15] vs. median 0.11 [interquartile range 0.06 to 0.22], P = .002).
Conclusion:
A relatively large T peaks cloud volume is associated with increased risk of VA in patients with structural heart disease and systolic dysfunction.
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Dysrhythmias III: Characteristics of Dysrhythmias