A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Feasibility study of near-infrared fluorescence tomography using a positron emission tomograph equipped with
Hideaki Tashima1, Takashi Obi, Taiga Yamaya
1Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Yokohama, Japan. tashima@isl.titech.ac.jp
Abstract:
We are currently developing an imaging system that combines simultaneous positron emission tomography (PET) with near-infrared (NIR) optical tomography, thus supporting two different types of molecular imaging. For this system, we are considering whether to use depth of interaction (DOI) PET detectors as simultaneous detectors of gamma rays and NIR light by changing the original upper reflectors to dichroic mirrors. The DOI-PET detector has very low spatial resolution for NIR light compared to the charge-coupled device cameras that are normally used. However, it is possible to reconstruct images of comparable value from the data acquired by low-resolution devices because the light is scattered by biological tissues and high-resolution devices are not necessarily effective at improving image quality. In this study, we demonstrate the feasibility of 3D NIR fluorescence tomography imaging by employing DOI-PET detectors in computer simulations. In the simulations, we used a 40 mm x 40 mm x 40 mm cubic phantom, a square detector geometry, and an optical diffusion equation to approximate the light propagation. We then evaluated imaging systems for 3D fluorescence tomography with different detector resolutions and excitation light arrangements using singular-value analysis and imaging simulation. We confirmed that the reconstructed images from low-resolution detectors (8 x 8 pixels for an area of 40 mm x 40 mm) are the same as those from high-resolution detectors (16 x 16 pixels for the same area).
More Related Videos
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET