Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Network Function of a Circuit01:25

Network Function of a Circuit

Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
Properties of Fourier Transform I01:21

Properties of Fourier Transform I

The application of Fourier Transform properties in radio broadcasting is multifaceted, enabling significant advancements in the way signals are transmitted and received. Key areas where these properties are utilized include simultaneous multi-channel transmission, audio clip speed adjustments, live broadcast delays for different time zones, audio frequency adjustments, and signal demodulation.
In radio broadcasting, multiple audio signals often need to be transmitted simultaneously. The Fourier...
Upsampling01:22

Upsampling

Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...
Frequency Response of Op Amp Circuits01:20

Frequency Response of Op Amp Circuits

Operational amplifiers (op-amp) are used in signal conditioning, filtering, or for performing mathematical operations such as addition, subtraction, integration, and differentiation. The frequency response of an op-amp is an important aspect that describes how the gain of the amplifier varies with frequency.
Frequency Response and Gain:
The gain of the op-amp, A(ω), is not a constant but a function of the input signal frequency. An op-amp can maintain a constant gain at low frequencies, known...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Noise-related inaccuracies in the quantitative evaluation of CT artifacts.

Radiological physics and technology·2025
Same author

Non-Contrast Enhanced MR Angiography in Pre-Procedural Assessment of Aortic Annulus for Transcatheter Aortic Valve Replacement.

The Tohoku journal of experimental medicine·2024
Same author

[The Models and Guides for Medical Professionals and Researchers to Perform Cost-utility Analysis of MRI Examinations: Part 2].

Nihon Hoshasen Gijutsu Gakkai zasshi·2024
Same author

[The Models and Guides for Medical Professionals and Researchers to Perform Cost-utility Analysis of MRI Examinations: Part 1].

Nihon Hoshasen Gijutsu Gakkai zasshi·2024
Same author

Denoising parameter dependence of coronary artery depictability in compressed sensing magnetic resonance angiography.

Radiological physics and technology·2024
Same author

Comparison of Slab and Pencil Beam Labeling in Spin-labeled MR Imaging for Pancreatic Juice Flow Visualization.

Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine·2023

Related Experiment Video

Updated: Jun 9, 2026

Generation and Coherent Control of Pulsed Quantum Frequency Combs
06:42

Generation and Coherent Control of Pulsed Quantum Frequency Combs

Published on: June 8, 2018

Deriving the modulation transfer function of CT from extremely noisy edge profiles.

Issei Mori1, Yoshio Machida

  • 1Health Sciences, Graduate School of Medicine, Tohoku University, Aoba-ku, Sendai, Japan. imori@mail.tains.tohoku.ac.jp

Radiological Physics and Technology
|September 8, 2010
PubMed
Summary

This study introduces a noise-robust edge spread function (ESF) method for X-ray CT modulation transfer function (MTF) analysis. The technique accurately estimates MTF even with low contrast-to-noise ratios (CNR), overcoming limitations of traditional methods.

More Related Videos

Studying Cavitation Enhanced Therapy
07:36

Studying Cavitation Enhanced Therapy

Published on: April 9, 2021

Related Experiment Videos

Last Updated: Jun 9, 2026

Generation and Coherent Control of Pulsed Quantum Frequency Combs
06:42

Generation and Coherent Control of Pulsed Quantum Frequency Combs

Published on: June 8, 2018

Studying Cavitation Enhanced Therapy
07:36

Studying Cavitation Enhanced Therapy

Published on: April 9, 2021

Area of Science:

  • Medical Imaging
  • Radiology
  • Image Quality Assessment

Background:

  • The point spread function (PSF) method is standard for X-ray CT modulation transfer function (MTF) but requires high contrast-to-noise ratio (CNR) and zooming reconstruction, limiting clinical applicability.
  • The edge spread function (ESF) method avoids zooming reconstruction but is sensitive to image noise, similar to the PSF method.

Purpose of the Study:

  • To develop a noise-robust edge spread function (ESF) method for determining the modulation transfer function (MTF) of X-ray CT systems under clinical conditions.
  • To enable accurate MTF assessment even with low contrast-to-noise ratios (CNR) and without specialized reconstruction techniques.

Main Methods:

  • A novel technique to enhance the robustness of the ESF method against image noise by applying multi-stage filtering to the noisy ESF.
  • Correction of blurring introduced in the line spread function (LSF) derived from the smoothed ESF, by deconvolution assuming Gaussian or multi-Gaussian line spread functions.
  • Validation of the method using images reconstructed with a soft-tissue imaging kernel.

Main Results:

  • The proposed ESF method effectively mitigates noise, allowing for reliable MTF estimation.
  • Accurate MTF values were obtained even with a low contrast-to-noise ratio (CNR) of 2.
  • The MTF derived from the noise-robust ESF method showed sufficient consistency with theoretical MTF values.

Conclusions:

  • The developed ESF-based technique offers a practical and robust alternative for X-ray CT MTF assessment in clinical settings.
  • This method overcomes the limitations of the PSF method and improves upon the standard ESF approach by effectively handling image noise.
  • Accurate modulation transfer function (MTF) determination is achievable even under challenging low contrast-to-noise ratio (CNR) conditions.