Effects of a novel ultrasound contrast agent with long persistence on right ventricular pressure: Comparison with SonoVue
Related Experiment Video
Updated: Jun 9, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Ping Liu1, Xiang Wang, Shiwen Zhou
1Department of Ultrasound, Xinqiao Hospital of the Third Military Medical University, Chongqing 400037, China.
Abstract:
This work investigated the effect of infusion of a self-made ultrasound contrast agent with long persistence (named ZHIFUXIAN) on rat right ventricular pressure and made a preliminary evaluation on the relative safety of the novel microbubbles. Normal saline, SonoVue and ZHIFUXIAN were injected through caudal vein at the total volume of 0.5ml for each injection. The right ventricular systolic pressure (RVSP) and end-diastolic pressure (RVEDP) were monitored and the changes of the pressure were compared with baseline readings. RVSP increased when saline, SonoVue or ZHIFUXIAN were injected, the greatest change being after SonoVue (about 2mmHg), but there was no statistical significance compared with baseline (P>0.05). There was no significant difference in RVSP between saline, SonoVue and ZHIFUXIAN at any time point. Also, there was no significant difference in RVEDP between groups at each time point and between different time points in each group. The results indicate that the self-made microbubbles effect on right ventricular hemodynamics is equivalent to that of normal saline at the same volume needed for effective enhanced imaging, demonstrating that it does not produce changes in right ventricular blood pressure under the study conditions. Pathological examination also showed it had no obvious influence on lung, liver and kidney.
More Related Videos
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation (SHAPE) Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
10:33Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: