Related Concept Videos

Microbial Biosensors01:17

Microbial Biosensors

Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...
Automated Microbial Diagnostics01:24

Automated Microbial Diagnostics

Automated diagnostic analyzers have transformed clinical microbiology by providing rapid and reliable methods for pathogen identification and antibiotic susceptibility testing. Among these systems, the Vitek 2 is widely used because it automates the traditionally labor-intensive processes of microbial identification (ID) and antibiotic susceptibility testing (AST), delivering standardized and timely results that are essential for effective patient care.Microbial Identification with ID CardsThe...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

From Tumour to Bloodstream: Advancing PD-L1 Testing With Liquid Biopsies in Non-Small Cell Lung Cancer.

Cytopathology : official journal of the British Society for Clinical Cytology·2026
Same author

The costs of an invasion: How the blue crab impaired ecosystem services in the most productive lagoon of northwestern Adriatic.

The Science of the total environment·2025
Same author

PFAS levels in fish species in the Po River (Italy): New generation PFAS, fish ecological traits and parasitism in the foreground.

The Science of the total environment·2023
Same author

Study on the association between sleep disorders versus oral health related variables.

Medicina oral, patologia oral y cirugia bucal·2020
Same author

Differential microRNA expression between decidual and peripheral blood natural killer cells in early pregnancy.

Human reproduction (Oxford, England)·2018
Same author

Correction to: EUROCAT: an update on its functions and activities.

Journal of community genetics·2018
Same journal

Four-in-one multifunctional CoCu-NC@AuPt nanozyme integrated M13 phage-displayed nanobody based multimodal lateral flow immunoassay for bovine lactoferrin detection.

Biosensors & bioelectronics·2026
Same journal

A novel capillary-driven dual-mode imaging flow cytometry system for malaria parasite detection and quantification.

Biosensors & bioelectronics·2026
Same journal

Liver-targeted alkaline phosphatase-activatable fluorescent probe for imaging liver fibrosis and screening anti-fibrotic natural products.

Biosensors & bioelectronics·2026
Same journal

GLASS-seq: a gel-anchored, ligation-assisted, scalable biosensing platform for low-cost regional spatial transcriptomics.

Biosensors & bioelectronics·2026
Same journal

CRISPR/Cas12a-based dual-modal signal platform using MIL-101(Fe) for colorimetric and electron spin resonance detection of HPV-16 nucleic acid.

Biosensors & bioelectronics·2026
Same journal

Fully automated centrifugal microfluidic system for self-calibrating isothermal nucleic acid quantification.

Biosensors & bioelectronics·2026
See all related articles

Related Experiment Video

Updated: Jun 8, 2026

Optical Detection of E. coli Bacteria by Mesoporous Silicon Biosensors
07:22

Optical Detection of E. coli Bacteria by Mesoporous Silicon Biosensors

Published on: November 20, 2013

An embedded portable biosensor system for bacterial concentration detection.

M Grossi1, M Lanzoni, A Pompei

  • 1Department of Electronic Engineering (DEIS), University of Bologna, Bologna, Italy. marco.grossi8@unibo.it

Biosensors & Bioelectronics
|September 14, 2010
PubMed
Summary
This summary is machine-generated.

Microbial screening is faster with the impedance technique (IT), offering an alternative to standard plate count (SPC). This method uses electrical changes to detect bacterial growth, enabling rapid and portable microbial analysis.

More Related Videos

Bacterial Detection & Identification Using Electrochemical Sensors
09:30

Bacterial Detection & Identification Using Electrochemical Sensors

Published on: April 23, 2013

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
08:22

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor

Published on: February 16, 2018

Related Experiment Videos

Last Updated: Jun 8, 2026

Optical Detection of E. coli Bacteria by Mesoporous Silicon Biosensors
07:22

Optical Detection of E. coli Bacteria by Mesoporous Silicon Biosensors

Published on: November 20, 2013

Bacterial Detection & Identification Using Electrochemical Sensors
09:30

Bacterial Detection & Identification Using Electrochemical Sensors

Published on: April 23, 2013

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
08:22

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor

Published on: February 16, 2018

Area of Science:

  • Microbiology
  • Electrical Engineering
  • Biotechnology

Background:

  • Traditional standard plate count (SPC) for microbial screening is accurate but time-consuming and requires laboratory settings.
  • The impedance technique (IT) offers a faster alternative by monitoring electrical changes caused by bacterial metabolism.

Purpose of the Study:

  • To evaluate the impedance technique (IT) as a rapid and portable method for microbial screening.
  • To compare IT results with standard plate count (SPC) for accuracy and efficiency.

Main Methods:

  • Bacterial metabolism-induced changes in the electrical characteristics of the sample under test (SUT) were measured using IT.
  • A 100 mV peak-to-peak 200 Hz sinusoidal test signal was applied at 5-min intervals.
  • A portable impedance measurement system with an incubation chamber and thermoregulation was developed.

Main Results:

  • Impedance measurements showed good correlation with SPC, especially for highly contaminated samples (10^6 cfu mL^-1) within 3 hours.
  • The IT method is significantly faster (3-12h) than SPC (24-72h).
  • The developed portable system facilitates microbial screening in various environments.

Conclusions:

  • The impedance technique (IT) is a viable, rapid, and efficient alternative to standard plate count (SPC) for microbial screening.
  • The portable impedance measurement system enables on-site microbial analysis in industrial and commercial settings.
  • This technology offers a cost-effective solution for fast microbial detection.