Related Experiment Video
Updated: Feb 19, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: a case report with 2.5 years
W Pirker1, D Wiedemann, A Lidauer
1Medical University Vienna, Austria.
Abstract:
This report demonstrates the clinical use of a modified, truly anatomic, root-analogue zirconia implant for immediate replacement of a two-rooted, left first mandibular molar. A 50-year-old female patient with chronic apical periodontitis of the left mandibulary first molar was referred and the tooth was extracted. The mesial root had to be removed surgically due to a root fracture. A truly anatomical, root identical, roughened zirconia implant modified by macro-retentions was manufactured and placed into the extraction socket by tapping 7 days later. After 4 months a composite crown was cemented in place. No complications occurred during the healing period. A good functional and aesthetic result was achieved with minimal bone resorption and soft tissue recession at 30 months follow-up. This report describes the successful clinical use of an immediate, single stage, truly anatomical root-analogue zirconia implant for replacement of a two-rooted tooth. Significant modifications such as macro-retentions yielded primary stability and excellent osseointegration. This novel approach is minimally invasive, respects the underlying anatomy, aids socket prevention, is time- and cost-saving with good patient acceptance as there is no need for bone drilling, sinus lift, bone augmentation or other traumatic procedures.

