Related Experiment Video
Updated: Jun 8, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Rapid urine drug screens: diphenhydramine and methadone cross-reactivity
Steven C Rogers1, Charles W Pruitt, Dennis J Crouch
1Connecticut Children's Medical Center, University of Connecticut School of Medicine, 282 Washington Street,Hartford, CT 06106, USA. scrogers@ccmckids.org
Background:
Rapid urine screens to detect drugs of abuse are often used in pediatric emergency departments (PEDs). A positive result may lead to further clinical testing, social evaluation, and increased stress/inconvenience. A PED patient with suspected diphenhydramine (DPH) ingestion had a positive methadone result on the rapid urine drug screen, One Step Multi-Drug, Multi-Line Screen Test Device (ACON Laboratories, San Diego, Calif). There was no history of methadone exposure so the patient was admitted while confirmatory testing was performed. Gas chromatography/mass spectroscopy testing of the urine failed to confirm the presence of methadone. We present this unreported false-positive methadone result and evaluation of the kit for cross-reactivity of DPH and methadone.
Methods:
The same One Step urine drug screen was tested at an independent laboratory for cross-reactivity between methadone and DPH including the DPH metabolites. Drug-free urine was fortified with DPH, nordiphenhydramine, or dinordiphenhydramine at 0, 10, 25, 50, and 100 μg/mL for each analyte. One hundred microliters of the solutions were added to each of the 4 wells on test cassettes. Urine was allowed to migrate according to manufacturer instructions. Each cassette was interpreted by 2 analysts to ensure consistent interpretation and accurate data recording.
Results:
In vitro laboratory testing results showed cross-reactivity between methadone and DPH but not for nordiphenhydramine or dinordiphenhydramine.
Conclusions:
Rapid urine drug screens using immunoassays based on the principle of competitive binding may show false-positive methadone results for patients who have ingested DPH. Product information for urine drug screens may not include all cross-reacting agents and should be used with caution when interpreting drug screen results in PED patients.
More Related Videos
Related Concept Videos
Drug Toxicity: Dose-Dependent Reactions
Drug Excretion: Miscellaneous Routes
Therapeutic Drug Monitoring: Drug Analysis Methods
Drug Abuse and Addiction: Pharmacological Phenomena
Nonlinear Pharmacokinetics: Dependence of Elimination Half-Life and Dose Clearance
A study on guinea pigs examined the...
Pharmacokinetics: Drug–Drug Interactions