Related Experiment Video
Updated: Jun 8, 2026

Electrochemically and Bioelectrochemically Induced Ammonium Recovery
Published on: January 22, 2015
Simulation studies of ammonia removal from water in a membrane contactor under liquid-liquid extraction mode
Amish Mandowara1, Prashant K Bhattacharya
1Department of Chemical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016, India.
Abstract:
Simulation studies were carried out, in an unsteady state, for the removal of ammonia from water via a membrane contactor. The contactor had an aqueous solution of NH(3) in the lumen and sulphuric acid in the shell side. The model equations were developed considering radial and axial diffusion and convection in the lumen. The partial differential equations were converted by the finite difference technique into a series of stiff ordinary differential equations w.r.t. time and solved using MATLAB. Excellent agreement was observed between the simulation results and experimental data (from the literature) for a contactor of 75 fibres. Excellent agreement was also observed between the simulation results and laboratory-generated data from a contactor containing 10,200 fibres. Our model is more suitable than the plug-flow model for designing the operation of the membrane contactor. The plug-flow model over-predicts the fractional removal of ammonia and was observed to be limited when designing longer contactors.