Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Effects on the dynamic utilization of the adsorptive capacity of chromatographic columns induced by non-uniform
Athanasios I Liapis1, Enrico Riccardi, Jee-Ching Wang
1Department of Chemical and Biological Engineering, Missouri University of Science and Technology, Rolla, MO 65409-1230, USA. ail@mst.edu
Abstract:
The dynamic behavior of the breakthrough curves of a single adsorbate obtained from columns employing adsorbent media which differ from one another only on the spatial distribution of the immobilized ligands in the porous particles is examined. The spatial distributions of the immobilized ligands considered in this study are uniform and non-uniform, but the total number of immobilized ligands in the particles has the same value whether the spatial distribution is uniform or non-uniform. The results clearly show that the columns employing adsorbent particles in which the spatial distribution of the immobilized ligands is non-uniform and such that the concentration of the immobilized ligands increases monotonically from the center of the particle to the outer particle surface, exhibit (i) larger breakthrough times, (ii) steeper breakthrough curves, and (iii) higher dynamic utilization of the adsorptive capacity of the column as the superficial velocity of the flowing fluid stream in the column increases (throughput increase) than the columns using adsorbent particles in which the spatial distribution of the immobilized ligands is uniform. The importance of employing in the columns adsorbent media whose spatial ligand density distributions satisfy the mathematical property of monotonically increasing ligand concentration with increasing from the particle center radial position, will be significantly enhanced when (i) the size of the particle radius is increased, and (ii) continuous counter-current and periodic counter-current (simulated moving beds) operations are employed.
Related Concept Videos
Analyte Adsorption and Distribution
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...