Related Experiment Video
Updated: Jun 8, 2026

Analyzing Long-Term Electrocardiography Recordings to Detect Arrhythmias in Mice
Published on: May 23, 2021
Effect of number of replicate electrocardiograms recorded at each time point in a thorough QT study on sample size
Mili Natekar1, Pooja Hingorani, Pallavi Gupta
1Quintiles Cardiac Safety Services, Research Section, 502A, Leela Business Park, M.V Road, Andheri East, Mumbai, India.
Abstract:
In a "thorough QT/QTc" (TQT) study, several replicate electrocardiograms (ECGs) are recorded at each time point to reduce within-subject variability. This decreases the sample size but increases the cost of ECG analysis. To determine the most cost-effective number of ECG replicates, the authors retrospectively analyzed data from the placebo and moxifloxacin arms of a TQT study with crossover design. Six replicate ECGs were recorded at 7 time points on day -1 (baseline day), day 1, and day 3 in 124 normal healthy volunteers who were randomized to receive moxifloxacin or placebo on day 1 and the other treatment on day 3. QT interval was corrected for heart rate by the Fridericia (QTcF) and individual subject-specific (QTcI) formulas. Within-subject and between-subject standard deviations for QTcF obtained by repeated-measures analysis of covariance were 9.5 and 13.3 milliseconds with 1 replicate; 7.8 and 12.7 milliseconds with 2 replicates; 7.3 and 12.3 milliseconds with 3 replicates; 6.9 and 12.2 milliseconds with 4 replicates; 6.8 and 11.9 milliseconds with 5 replicates; and 6.6 and 11.8 milliseconds with 6 replicates. Within- and between-subject variance with QTcI also declined with increasing replicates. Sample size benefit based on these estimates was negligible beyond 4 replicates. The study cost was least with 3 or 4 replicates, depending on per-ECG and per-subject costs.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Dysrhythmias V: Evaluating Dysrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...