Jove
Visualize
Contact Us

Related Concept Videos

Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview01:13

Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview

Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
Radiation: Applications01:17

Radiation: Applications

The average temperature of Earth is the subject of much current discussion. Earth is in radiative contact with both the Sun and dark space; it receives almost all its energy from the radiation of the Sun and reflects some of it into outer space. Dark space is very cold, about 3 K, so Earth radiates energy into it. For instance, heat transfer occurs from soil and grasses, the rate of which can be so rapid that frost can occur on clear summer evenings, even in warm latitudes.
The average...
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Effect of dapagliflozin on the serum metabolome in patients with type 2 diabetes mellitus.

Journal of diabetes and metabolic disorders·2024
Same author

NMR-based metabolomic signature: An important tool for the diagnosis and study of pathogenesis of autoimmune hepatitis.

Hepatology (Baltimore, Md.)·2024
Same author

Craniofacial Development Is Fine-Tuned by Sox2.

Genes·2023
Same author

A Study of the Metabolic Pathways Affected by Gestational Diabetes Mellitus: Comparison with Type 2 Diabetes.

Diagnostics (Basel, Switzerland)·2022
Same author

The Critical Role of the Branched Chain Amino Acids (BCAAs) Catabolism-Regulating Enzymes, Branched-Chain Aminotransferase (BCAT) and Branched-Chain α-Keto Acid Dehydrogenase (BCKD), in Human Pathophysiology.

International journal of molecular sciences·2022
Same author

Optimization of psoriasis mouse models.

Journal of pharmacological and toxicological methods·2021
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 8, 2026

Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy
09:25

Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy

Published on: August 22, 2018

Simple two-layer reflectance model for biological tissue applications: lower absorbing layer.

George Zonios1, Aikaterini Dimou

  • 1Department of Materials Science and Engineering, University of Ioannina, 45110 Ioannina, Greece. gzonios@alum.mit.edu

Applied Optics
|September 22, 2010
PubMed
Summary
This summary is machine-generated.

This study presents a two-layer tissue reflectance model for noninvasive optical studies. The model estimates epithelial tissue parameters, aiding in the analysis of biological tissues.

More Related Videos

Multimodal Imaging and Spectroscopy Fiber-bundle Microendoscopy Platform for Non-invasive, In Vivo Tissue Analysis
10:35

Multimodal Imaging and Spectroscopy Fiber-bundle Microendoscopy Platform for Non-invasive, In Vivo Tissue Analysis

Published on: October 17, 2016

An Intra-Tissue Radiometry Microprobe for Measuring Radiance In Situ in Living Tissue
09:10

An Intra-Tissue Radiometry Microprobe for Measuring Radiance In Situ in Living Tissue

Published on: June 2, 2023

Related Experiment Videos

Last Updated: Jun 8, 2026

Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy
09:25

Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy

Published on: August 22, 2018

Multimodal Imaging and Spectroscopy Fiber-bundle Microendoscopy Platform for Non-invasive, In Vivo Tissue Analysis
10:35

Multimodal Imaging and Spectroscopy Fiber-bundle Microendoscopy Platform for Non-invasive, In Vivo Tissue Analysis

Published on: October 17, 2016

An Intra-Tissue Radiometry Microprobe for Measuring Radiance In Situ in Living Tissue
09:10

An Intra-Tissue Radiometry Microprobe for Measuring Radiance In Situ in Living Tissue

Published on: June 2, 2023

Area of Science:

  • Biomedical Optics
  • Biophotonics
  • Optical Modeling

Background:

  • Accurate modeling of light interaction with biological tissues is crucial for noninvasive diagnostic techniques.
  • Existing models often simplify tissue structures, limiting their applicability to complex biological systems.
  • Understanding light scattering and absorption properties of different tissue layers is essential for optical imaging and sensing.

Purpose of the Study:

  • To introduce a refined two-layer tissue reflectance model.
  • To simulate light interaction in a realistic epithelial and stromal tissue configuration.
  • To enable noninvasive estimation of key tissue optical parameters.

Main Methods:

  • Development of a two-layer optical model with distinct upper (scattering-only) and lower (absorbing and scattering) layers.
  • Mathematical formulation of light reflectance based on layer properties and thickness.
  • Validation of the model using tissue phantoms in both forward (prediction) and inverse (estimation) modes.

Main Results:

  • The model successfully estimates tissue parameters like upper layer thickness and lower layer absorption coefficients.
  • The model's accuracy and validity range were confirmed through experimental testing on tissue phantoms.
  • Demonstrated the model's potential for analyzing epithelial tissues in visible and near-infrared spectral regions.

Conclusions:

  • The developed two-layer reflectance model offers a valuable tool for noninvasive optical characterization of biological tissues.
  • This model provides a more realistic representation of epithelial and stromal layers, enhancing diagnostic capabilities.
  • Further applications include quantitative optical imaging and monitoring of epithelial tissue health.