Pediatric 99mTc-MDP bone SPECT with ordered subset expectation maximization iterative reconstruction with isotropic
Eryn Caamano Stansfield1, Niall Sheehy, David Zurakowski
1Joint Program in Nuclear Medicine, Harvard Medical School, Boston, Mass, USA.
Purpose:
To perform a preliminary evaluation of the image quality of pediatric technetium 99m ((99m)Tc) methylene diphosphonate (MDP) bone single photon emission computed tomography (SPECT) by using iterative reconstruction-ordered subset expectation maximization with three-dimensional resolution recovery (OSEM-3D)-and to assess whether any improvements with use of this technique could lead to a reduction in patient dose or a shortening in imaging time.
Materials And Methods:
Institutional advisory board approval was obtained for this investigation. Fifty (99m)Tc-MDP SPECT studies of the spine were evaluated (36 female and 14 male patients; mean age, 15.5 years). Each study was acquired by using a dual-detector camera, with each detector rotating 360°. By using filtered back projection (FBP) and OSEM-3D, images were reconstructed from data generated by both detectors. Likewise, OSEM-3D was used to reconstruct data from a single detector simulating half the administered radiopharmaceutical activity. Two nuclear medicine physicians, blinded to the patient data, reviewed the images for image quality in four different categories by using a four-point scale: artifacts (category 1), lesions (category 2), noise (category 3), and image sharpness (category 4).
Results:
Compared with FBP, images reconstructed by using OSEM-3D with one or two detectors showed significant improvement in image quality with regard to lesion detection, noise level, and image sharpness (P < .02, .01, and .001, respectively). With OSEM-3D, no significant differences were observed when either one or two detectors were used.
Conclusion:
Improved image quality of skeletal SPECT with either a 50% reduction in radiation dose or a 50% reduction in acquisition time or combination of the two can be achieved by using OSEM-3D.