Related Experiment Video
Updated: Jun 8, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
The performance of zirconium dioxide crowns: a clinical follow-up
1Department of Prosthodontics, Section of Medical Materials and Technology, Center of Dentistry, Oral Medicine, and Maxillofacial Surgery Tübingen, Tübingen, Germany. martin.groten@med.uni-tuebingen.de
Abstract:
Thirty-two patients who had been treated with 71 computer-aided design/computer-assisted manufacture-fabricated Cercon crowns were followed to assess clinical performance by time-to-event analysis. Clinical examinations consisted of a complete dental and oral hygiene examination and a quality assessment by modified California Dental Association criteria. Four patients (6 crowns) were lost to follow-up; another 11 crowns had to be excluded from evaluation for comparability reasons. Six of 54 evaluated crowns experienced complications (P(C) = 11.1%) throughout a mean observation time of 21 months. Survival was estimated at 0.98 over 24 months. The good overall clinical performance was affected predominantly by technical complications of the veneering ceramic (P(TC) = 9.3%).