Related Experiment Video
Updated: Jun 8, 2026

Cooling Rate Dependent Ellipsometry Measurements to Determine the Dynamics of Thin Glassy Films
Published on: January 26, 2016
New nearly constant loss feature detected in glass at low temperatures
David M Laughman1, Radha D Banhatti, Klaus Funke
1Institute of Physical Chemistry and Sonderforschungsbereich 458, University of Münster, Corrensstrasse 30, D - 48149 Münster, Germany.
Abstract:
At sufficiently low temperatures, disordered ionic materials display the well-known Nearly Constant Loss (NCL) effect, with ionic conductivities becoming approximately proportional to frequency and virtually independent of temperature. There is a broad consensus that the effect is a collective phenomenon, with many interacting ions participating, each of them performing some non-vibrational motion that remains strictly localised. The underlying many-particle dynamics have been analysed in Monte Carlo simulations and also by straightforward modelling. Both kinds of treatment predict that, with decreasing frequency, a frequency squared behaviour should become visible. Here, we report on the experimental detection of the squared to linear crossover in an NCL component of conductivity spectra of sodium borate glasses, xNa(2)O·(1 -x) B(2)O(3) with x = 0.05 and x = 0.1, at temperatures below 100 K. From the composition dependence of the effect it is obvious that it is caused by the sodium ions. We demonstrate that this behaviour corresponds to an almost trivial property of the mean square displacement of the confined, but locally mobile ions, which approaches a temperature-independent long-time value, reflecting the finite size of the accessible volume. In the log-log plot of measured conductivity versus frequency, the transition from slope two to slope one is rather gradual, reflecting the existence of different local neighbourhoods of the sodium ions.
Related Concept Videos
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Constant Volume Calorimetry
Boundary Conditions: Lossless Lines
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
Constant Pressure Calorimetry
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction facilitates the...