Background:
Spiral enteroscopy (SE) has emerged as a new alternative for deep intubation of the small intestine. SE is most often used to evaluate abnormal findings on capsule endoscopy (CE).
Objective:
Investigate the ability of SE to reproduce abnormal findings detected on preceding CE.
Design:
Prospective study.
Setting:
Two academic tertiary care centers.
Patients:
Consecutive patients undergoing SE to investigate a clinically significant finding on CE.
Main Outcome Measurement:
Ability of SE to identify findings on CE.
Results:
Total of 56 anterograde SE procedures were performed. CE findings included arteriovenous malformations (AVMs) (n=26), masses (n=8), ulcers (n=4), polyps (n=4), abnormal mucosa (n=6), fresh blood (n=6), and stricture (n=1). Majority of the patients had CE findings located in the jejunum (41 of 56 or 73.2%). Mean depth of enteroscope insertion was 224.6±68.7 cm. SE detected relevant small bowel pathology in 32 of 56 (57.1%) patients. Findings on CE were reproduced in 30 of 56 (53.6%) cases. Reproducibility was independent of patient body mass index (P=0.38), CE indication (P=0.24), CE lesion location (P=0.29), days between CE and SE (P=0.30), and depth of insertion (P=0.81). Type of CE findings (particularly AVMs) significantly affected SE reproducibility (P=0.015). SE procedure time was inversely related to SE reproducibility (odds ratio=0.94, 95% confidence interval=0.88-0.99, P=0.02).
Limitations:
Small sample size and potential for false-positive CE study.
Conclusions:
SE seems to be moderately effective (57.1%) in terms of its ability to locate pathology within the small intestine. The type of small bowel pathology targeted by SE may affect its clinical utility. AVMs observed on CE can be seen at the time of SE in the majority of cases (60%).
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Procedures II: Colonoscopy
Urologic Endoscopic Procedure: Cystoscopic Examination
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...