Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
IR Frequency Region: Fingerprint Region01:03

IR Frequency Region: Fingerprint Region

IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the C=O, C=N, and C=C occur between 1600–1850 cm−1.
The...
Infrared (IR) Spectroscopy: Overview01:09

Infrared (IR) Spectroscopy: Overview

When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
IR Spectrum01:19

IR Spectrum

When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
IR Absorption Frequency: Hybridization01:21

IR Absorption Frequency: Hybridization

Hydrocarbons such as alkanes, alkenes, and alkynes show characteristic C–H stretching absorption bands. These IR stretching frequencies depend on the hybridization of the involved carbon atom and can be explained in terms of the s character of each hybridized atomic orbital.
Among the sp, sp2, and sp3 hybridized orbitals, sp orbitals have the maximum s character (50%). Consequently, the electrons are held more closely to the nucleus, resulting in stronger and shorter C–H bonds that stretch at a...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview01:13

Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview

Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Colposcopy Quality Control: Establishing Colposcopy Criterion Standards for the National Cancer Institute ALTS Trial Using Cervigrams.

Journal of lower genital tract disease·2015
Same author

HPV DNA Testing by Hybrid Capture Does Not Appear to be Useful in the Triage of Cytology Read as ASCUS-Favor Dysplasia, or as LGSIL.

Journal of lower genital tract disease·2015
Same author

Advanced Technologies in Cervical Cancer Screening ASCCP Biennial Meeting 1998.

Journal of lower genital tract disease·2015
Same author

ASCCP Practice Committee.

Journal of lower genital tract disease·2015
Same author

ASCCP Practice Guidelines: The Follow-Up System for Abnormal Cervical Cytological Findings.

Journal of lower genital tract disease·2015
Same author

Will human papillomavirus testing find a niche?

Journal of lower genital tract disease·2015
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: Jun 8, 2026

Measuring Magnetically-Tuned Ferroelectric Polarization in Liquid Crystals
07:03

Measuring Magnetically-Tuned Ferroelectric Polarization in Liquid Crystals

Published on: August 15, 2018

Infrared absorber for ferroelectric detectors.

V T Bly, J T Cox

    Applied Optics
    |September 24, 2010
    PubMed
    Summary
    This summary is machine-generated.

    A novel metal-dielectric coating achieves over 98% infrared absorption across a broad spectrum. This nearly ideal IR absorber is suitable for advanced ferroelectric and infrared detectors.

    More Related Videos

    A Fabrication and Measurement Method for a Flexible Ferroelectric Element Based on Van Der Waals Heteroepitaxy
    10:40

    A Fabrication and Measurement Method for a Flexible Ferroelectric Element Based on Van Der Waals Heteroepitaxy

    Published on: April 8, 2018

    In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
    07:03

    In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography

    Published on: May 30, 2020

    Related Experiment Videos

    Last Updated: Jun 8, 2026

    Measuring Magnetically-Tuned Ferroelectric Polarization in Liquid Crystals
    07:03

    Measuring Magnetically-Tuned Ferroelectric Polarization in Liquid Crystals

    Published on: August 15, 2018

    A Fabrication and Measurement Method for a Flexible Ferroelectric Element Based on Van Der Waals Heteroepitaxy
    10:40

    A Fabrication and Measurement Method for a Flexible Ferroelectric Element Based on Van Der Waals Heteroepitaxy

    Published on: April 8, 2018

    In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
    07:03

    In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography

    Published on: May 30, 2020

    Area of Science:

    • Materials Science
    • Optics
    • Physics

    Background:

    • Infrared (IR) detectors require efficient absorption materials.
    • Existing IR absorbers often have limited spectral bandwidth or efficiency.

    Purpose of the Study:

    • To develop a nearly ideal IR absorber coating.
    • To demonstrate high absorption (>98%) over a wide spectral band for IR detectors.

    Main Methods:

    • Design and fabrication of a thin-film metal-dielectric coating.
    • Optical characterization of the coating's absorption properties.
    • Theoretical modeling of the optical design.

    Main Results:

    • Achieved IR absorption exceeding 98% over a two-to-one spectral band.
    • Experimental data showed excellent agreement with theoretical predictions.
    • Demonstrated the coating's suitability for ferroelectric and related IR detectors.

    Conclusions:

    • The developed metal-dielectric coating represents a significant advancement in IR absorption technology.
    • This coating offers high performance for demanding IR detection applications.
    • The theoretical framework accurately predicts the experimental performance of the absorber.