Related Experiment Video
Updated: Jun 8, 2026

Mass Isolation and In Vitro Cultivation of Intramolluscan Stages of the Human Blood Fluke Schistosoma Mansoni
Published on: January 14, 2018
Factors affecting the concentration of electrolyte infusions prepared from stock solutions
Thomas M Donaldson1, Vaithianadan Mani, Daniel W Wheeler
1School of Clinical Medicine, University of Cambridge, Addenbrooke's Hospital, Cambridge, UK.
Background:
Wide variation in the concentrations of electrolyte infusions prepared from stock solutions has previously been reported. Layering of viscous stock electrolyte solutions in their diluent can lead to high concentrations being delivered during the infusion, resulting in potentially very serious medication errors which have caused deaths.
Objective:
To determine the safest way of preparing homogenous electrolyte solutions for parenteral infusion.
Methods:
The study examined how the concentration of potassium and magnesium varied during infusions after concentrated stock solutions had been diluted to 400 mmol/l with 0.9% sodium chloride. It also examined the use of syringes compared to polyvinyl chloride (PVC) bags, agitating vigorously with a 'vortex' mixer compared to inversion, and the influence of allowing the infusions to stand for 24 h before administration. The study was conducted in November 2009. Results It was found that, in general, the concentrations of potassium and magnesium solutions are less variable if they are prepared in PVC bags rather than syringes. Vigorous mixing of concentrated stock solutions with diluent and allowing preparations to stand for 24 h also improved the homogeneity of the infusions. However, even with meticulous preparation, some infusions deviated from the expected concentration by more than 10%.
Conclusion:
It is recommended that electrolyte infusions are prepared and provided by the pharmaceutical industry in prefilled syringes or bags. Given the likely cost of these products, an alternative would be to prepare infusions in pharmacy in advance, using PVC bags rather than syringes, and that they should be agitated vigorously with a 'vortex' mixer.
Related Concept Videos
Electrolytes: van't Hoff Factor
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Solution Concentration and Dilution
Ionic Strength: Effects on Chemical Equilibria
In this solution, the primary cation—the calcium...
Factors Affecting Solubility
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...