Comparison of accuracy and time-efficiency of CT colonography between conventional and panoramic 3D interpretation
Joon-Il Choi1, Se Hyung Kim, Seung Ho Kim
1Department of Radiology, Seoul Saint Mary's Hospital, The Catholic University of Korea, 505 Banpo-dong, Seocho-gu, Seoul, Republic of Korea. dumky@catholic.ac.kr
Purpose:
To retrospectively compare the conventional three-dimensional (3D) interpretation method with the panoramic 3D method with regard to accuracy and time-efficiency in the detection of colonic polyps, using pig colonic phantoms as the standard of reference.
Materials And Methods:
One-hundred and sixty-two polyps were created in 18 pig colonic phantoms. CT colonography was performed with a 64-row detector CT scanner. Two-week interval reviews for the CTC image dataset with both the conventional and the panoramic 3D interpretation method were independently performed by three radiologists. The sensitivities of both methods were compared with the McNemar test. The mean interpretation time for each interpretation method was also assessed and compared with the Wilcoxon signed-rank test.
Results:
Compared with the conventional 3D method (0.96 for reader 1, 0.89 for reader 2, and 0.97 for reader 3), the panoramic method revealed comparable sensitivities (0.91 for reader 1, 0.86 for reader 2, and 0.93 for reader 3) (p>0.05). Interpretation time was significantly shorter with the panoramic method (115.1±32.7 s for reader 1, 229.7±72.2 s for reader 2, and 282.6±113.7 s for reader 3) than with the conventional method (218.9±59.9 s for reader 1, 379.4±117.0 s for reader 2, and 458.7±149.4 s for reader 3) for all readers (p<0.05).
Conclusion:
Compared with the conventional 3D interpretation method, the panoramic 3D interpretation method shows improved time-efficiency and comparable sensitivity in the detection of colonic polyps.
More Related Videos
09:57Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT