Kinetic model-based factor analysis of dynamic sequences for 82-rubidium cardiac positron emission tomography
R Klein1, R S Beanlands, R W Wassenaar
1National Cardiac PET Centre, University of Ottawa Heart Institute, Ontario, Canada.
Purpose:
Factor analysis has been pursued as a means to decompose dynamic cardiac PET images into different tissue types based on their unique temporal signatures to improve quantification of physiological function. In this work, the authors present a novel kinetic model-based (MB) method that includes physiological models of factor relationships within the decomposition process. The physiological accuracy of MB decomposed (82)Rb cardiac PET images is evaluated using simulated and experimental data. Precision of myocardial blood flow (MBF) measurement is also evaluated.
Methods:
A gamma-variate model was used to describe the transport of (82)Rb in arterial blood from the right to left ventricle, and a one-compartment model to describe the exchange between blood and myocardium. Simulations of canine and rat heart imaging were performed to evaluate parameter estimation errors. Arterial blood sampling in rats and (11)CO blood pool imaging in dogs were used to evaluate factor and structure accuracy. Variable infusion duration studies in canine were used to evaluate MB structure and global MBF reproducibility. All results were compared to a previously published minimal structure overlap (MSO) method.
Results:
Canine heart simulations demonstrated that MB has lower root-mean-square error (RMSE) than MSO for both factor (0.2% vs 0.5%, p < 0.001 MB vs MSO, respectively) and structure (3.0% vs 4.7%, p < 0.001) estimations, as with rat heart simulations (factors: 0.2% vs 0.9%, p < 0.001 and structures: 3.0% vs 6.7%, p < 0.001). MB blood factors compared to arterial blood samples in rats had lower RMSE than MSO (1.6% vs 2.2%, p =0.025). There was no difference in the RMSE of blood structures compared to a (11)CO blood pool image in dogs (8.5% vs 8.8%, p =0.23). Myocardial structures were more reproducible with MB than with MSO (RMSE=3.9% vs 6.2%, p < 0.001), as were blood structures (RMSE=4.9% vs 5.6%, p =0.006). Finally, MBF values tended to be more reproducible with MB compared to MSO (CV= 10% vs 18%, p =0.16). The execution time of MB was, on average, 2.4 times shorter than MSO (p < 0.001) due to fewer free parameters.
Conclusions:
Kinetic model-based factor analysis can be used to provide physiologically accurate decomposition of (82)Rb dynamic PET images, and may improve the precision of MBF quantification.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
14:21Creating Dynamic Images of Short-lived Dopamine Fluctuations with lp-ntPET: Dopamine Movies of Cigarette Smoking
Published on: August 6, 2013
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...