Purpose:
Electroencephalogram (EEG) source analysis is a noninvasive technique used in the presurgical of epilepsy. In this study, the dipole location and orientation errors due to skull conductivity perturbations were investigated in two groups of three-dimensional head models: A spherical head model and a realistic head model.
Methods:
In each group, the head model had a brain-to-skull conductivity ratio (Rsigma) within the range of 10-40. Solving the forward problem in the head model with skull conductivity perturbations along with the inverse problem in the baseline head model with Rsigma=20 permitted the derivation of the dipole estimation errors.
Results:
Perturbations in the skull conductivity generated dipole location and orientation errors: The larger the perturbations, the larger the errors and the error ranges. The dipole orientation error due to skull conductivity perturbations was not great (maximal mean of < 5 degrees) in this study, but the dipole location error was notable (maximal mean of > 5 mm).
Conclusions:
Therefore, the influence of skull conductivity perturbations on EEG dipole source analysis cannot be neglected. This study suggests that it is necessary to measure the skull conductivity of the individual patients in order to achieve accurate EEG source analysis.
Related Concept Videos
Electric Dipoles and Dipole Moment
Theoretically, studying electric dipoles leads to understanding why the resultant electric forces around us are weak. Since electric forces are strong, remnant net charges are rare. Hence, the interaction between dipoles helps us understand electrical interactions in...
Bond Polarity, Dipole Moment, and Percent Ionic Character
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
Induced Electric Dipoles
Since the absolute value of potential energy holds no physical meaning, its zero value can be chosen as per...
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...