Monitoring alterations in fingertip temperature during ischaemia and the subsequent hyperaemia provides a novel way of studying microvascular reactivity. The relations between parameters characterizing blood perfusion and the thermal response of fingertips were studied using experimental and theoretical approaches. During the experimental protocol, two brachial artery occlusion tests were conducted in 12 healthy volunteers, and fingertip temperature, heat flux and skin perfusion using laser Doppler flowmetry (LDF) were measured. The temperature curves provide a smooth and robust response that is able to capture occlusion and reperfusion. The temperature fall during occlusion as well as the maximum temperature recorded depended linearly on the initial temperature. The magnitude of the LDF signal was associated with local tissue temperature and followed an exponential response. Heat flux measurements demonstrated rapid changes and followed variations in blood perfusion closely. The time points at which the heat flux reached its maximum corresponded to the time at which the fingertip temperature curves showed an inflection point after cuff release. The time required for the fingertip temperature to arrive at the maximum temperature was greater than the time to peak for the heat flux signal, which was greater than the LDF signal to reach a maximum. The time lag between these signals was a function of the finger size and finger temperature at the moment reperfusion restarted. Our present results indicate that finger temperature, heat flux and perfusion display varying rates of recovery following ischaemic stimuli and that differential responses are associated with the initial finger temperature.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Responses to Heat and Cold Stress
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermosensation
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.