Enzyme-Linked Immunosorbent Assay01:33

Enzyme-Linked Immunosorbent Assay

18.0K
In 1971, Peter Perlman and Eva Engvall developed an Enzyme-linked immunosorbent assay (ELISA or EIA). ELISA differs from western blot in that the assays are conducted in microtiter plates or in vivo rather than on an absorbent membrane.
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen.  Enzyme-substrate reaction allows the antigen to be visualized or...
18.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Corrigendum to "Environmental monitoring of a climate change indicator (Vibrio vulnificus) in coastal wetland water samples based on field-deployable detection [Sci. Total Environ. 986: 179791]".

The Science of the total environment·2025
Same author

Drying-Induced Salt Deposition Patterns as a Tool for Label-Free Protein Quantification.

Biosensors·2025
Same author

Synthetic biology-driven optoelectronic biosensor for rapid and highly sensitive norovirus detection in fecal samples.

Biosensors & bioelectronics·2025
Same author

Surface Relief Gratings of Slide-Ring Hydrogels for Label-Free Biosensing.

Gels (Basel, Switzerland)·2025
Same author

Environmental monitoring of a climate change indicator (Vibrio vulnificus) in coastal wetland water samples based on field-deployable detection.

The Science of the total environment·2025
Same author

Portable electrophoretic lateral flow biosensing for ultra-sensitive human lactate dehydrogenase detection in serum samples.

Biosensors & bioelectronics·2025

Related Experiment Video

Updated: Mar 4, 2026

A High-Throughput Electrochemiluminescence 7-Plex Assay Simultaneously Screening for Type 1 Diabetes and Multiple Autoimmune Diseases
06:50

A High-Throughput Electrochemiluminescence 7-Plex Assay Simultaneously Screening for Type 1 Diabetes and Multiple Autoimmune Diseases

Published on: May 29, 2020

3.1K

Direct hapten-linked multiplexed immunoassays on polycarbonate surface.

Jesús Tamarit-López1, Sergi Morais, Rosa Puchades

  • 1Departamento de Química, Instituto de Reconocimiento Molecular y Desarrollo Tecnológico, Universidad Politécnica de Valencia, Camino de Vera s/n, 46071 Valencia, Spain.

Biosensors & Bioelectronics
|October 1, 2010
PubMed
Summary

A novel direct hapten-linked multiplexed immunoassay was developed on Digital Versatile Discs (DVDs) for detecting environmental pollutants. This method offers improved sensitivity and reduced cross-interference for high-throughput multianalysis.

More Related Videos

Snap Chip for Cross-reactivity-free and Spotter-free Multiplexed Sandwich Immunoassays
10:44

Snap Chip for Cross-reactivity-free and Spotter-free Multiplexed Sandwich Immunoassays

Published on: November 13, 2017

6.9K
Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
09:08

Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens

Published on: September 12, 2016

9.2K

Related Experiment Videos

Last Updated: Mar 4, 2026

A High-Throughput Electrochemiluminescence 7-Plex Assay Simultaneously Screening for Type 1 Diabetes and Multiple Autoimmune Diseases
06:50

A High-Throughput Electrochemiluminescence 7-Plex Assay Simultaneously Screening for Type 1 Diabetes and Multiple Autoimmune Diseases

Published on: May 29, 2020

3.1K
Snap Chip for Cross-reactivity-free and Spotter-free Multiplexed Sandwich Immunoassays
10:44

Snap Chip for Cross-reactivity-free and Spotter-free Multiplexed Sandwich Immunoassays

Published on: November 13, 2017

6.9K
Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
09:08

Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens

Published on: September 12, 2016

9.2K

Area of Science:

  • Environmental Science
  • Analytical Chemistry
  • Biotechnology

Background:

  • Multiplexed immunoassays are crucial for detecting multiple environmental contaminants simultaneously.
  • Traditional methods often face limitations in sensitivity and cross-interference.
  • Developing cost-effective and high-throughput platforms is essential for environmental monitoring.

Purpose of the Study:

  • To develop a direct hapten-linked multiplexed immunoassay on a Digital Versatile Disc (DVD) platform.
  • To demonstrate the feasibility of using DVDs as a substrate for sensitive and specific environmental analyte detection.
  • To compare the performance of DVD-based sensing with other immunoassay formats.

Main Methods:

  • Carboxylated haptens were directly immobilized onto an aminated polycarbonate DVD surface using carbodiimide/succinimide coupling.
  • A multiplexed immunoassay was performed on the modified DVD surface for six target environmental compounds.
  • Detection limits were determined for chlorpyrifos, 2,4,5-trichlorophenoxypropionic acid, sulfathiazole, sulfasalazine, fenthion, and malathion.

Main Results:

  • The modified DVD surface retained its physical and optical properties.
  • The assay achieved detection limits as low as 0.1 μg/L for four analytes and 1.0 μg/L for two others.
  • The direct hapten-linking approach showed improved sensitivity and no cross-interference compared to protein-hapten conjugates.
  • The DVD disc and drive sensing strategy proved simpler, more reproducible, and offered higher signal-to-noise ratios.

Conclusions:

  • Direct hapten-linked multiplexed immunoassay on DVDs is a viable and advantageous approach for environmental monitoring.
  • This method enhances sensitivity and reduces cross-interference, enabling high-throughput multianalysis.
  • The DVD platform offers a simple, reproducible, and cost-effective solution for detecting environmental contaminants.