Related Experiment Video
Updated: Jun 8, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Unusual presentation of active implant periapical lesions: a report of two cases
Guilherme C Silva1, Davidson R F Oliveira, Tainah C Vieira
1Department of Restorative Dentistry, School of Dentistry, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil. guilhermeccs@ufmg.br
Abstract:
Active implant periapical lesion (IPL) is a rare lesion which has been reported as one of the causes of dental implant failures. Usually, an affected implant shows radiolucency in the apical area, while remaining clinically stable. IPL is often accompanied by symptoms of pain, swelling, tenderness, and fistulation. In this paper, we describe two cases of IPL with very unusual findings which led to implant failure. A large IPL associated with an inflammatory cyst in the anterior maxilla, and a mandibular IPL resulting in an extra-oral fistula are presented. The etiology and treatment approaches for IPL are discussed.