Related Experiment Video
Updated: Jun 8, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Is there a role for BLADE acquisition in T2-weighted breast MRI?
Umit Aksoy Ozcan1, Alp Dincer, M Erdem Yildiz
1Department of Radiology, Acibadem University School of Medicine, Istanbul. uozcan@asg.com.tr
Background:
standard T2-weighted (T2W) magnetic resonance imaging (MRI) is a necessary component of routine breast MRI. However, breast MRI suffers from minor subject movements, which degrade the image quality. BLADE acquisition MRI is a promising motion degradation method currently used in brain imaging.
Purpose:
to compare T2W BLADE acquisition breast MR images with routine T2W images in the evaluation of motion artifacts and overall image quality.
Material And Methods:
MRI was performed with a 1.5 T system on 25 volunteers and 25 consecutive patients with identical imaging parameters for both MRI sequences (TR 5240 ms, TE 112-108 ms, acquisition 1, spatial resolution 0.9×0.9× 4 mm). Motion and flow artifacts and pectoral muscle and lesion contour delineations were assessed. Signal to noise ratios (SNRs) of images and contrast to noise ratios (CNRs) of the incidental lesions were calculated. The results were evaluated with the Wilcoxon signed-ranks test.
Results:
of the 50 patients, 44 were included in the analysis (mean age 42.1 years). Motion artifacts were prominent in 48% cases on routine T2W and in only 2% of BLADE cases. The SNR values of BLADE images were significantly higher than routine T2W (P<0.05). Pectoral muscle contours were better assessed on BLADE in all cases. Sequence performances were similar in flow artifacts, CNR values, and contour delineation of incidental lesions. The readers chose BLADE sequence MRI in 25 cases and found the overall performance of sequences equal in 19 cases. None of the readers preferred routine T2W to BLADE.
Conclusion:
the performance of BLADE is superior to routine T2W images in eliminating motion artifacts, provides better SNRs, shows detailed pectoral muscle contours, and may be the sequence of choice.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...