Related Experiment Video
Updated: Jun 8, 2026

Hickman Catheter Use for Long-Term Vascular Access in a Preclinical Swine Model
Published on: March 31, 2023
Bovine jugular vein valved conduit: up to 10 years follow-up
Natasha Prior1, Nelson Alphonso, Philip Arnold
1Department of Cardiac Surgery, Alder Hey Children National Health Service Foundation Trust, Liverpool, United Kingdom.
Objective:
The present study evaluated the mortality and conduit failure in bovine jugular vein (BJV) conduits.
Methods:
Between October 1999 and February 2009, 193 patients (mean age, 6.7 ± 5.8 years; range, 5 days to 18 years; mean weight, 23.9 ± 21.0 kg; range, 2.4-105.4 kg) had been discharged after BJV implantation. The reason for BJV implantation was right ventricular outflow tract reconstruction in 117 conduit replacement in 44, and the Ross procedure in 32. The diameter of the BJV was 12 mm in 18 patients (9.3%), 14 mm in 16 (8.3%), 16 mm in 42 (21.7%), 18 mm in 37 (19.2%), 20 mm in 15 (7.8%), and 22 mm in 65 (33.7%).
Results:
At a mean ± SD follow-up of 4.6 ± 2.3 y/patient (range, 8 months to 10 years), 5 late deaths (2.6%) had occurred, all unrelated to conduit failure. Conduit-related problems required an interventional procedure as the first treatment in 10 patients (5.2%) within a mean interval of 2.5 ± 1.4 years (range, 8 months to 5.3 years) or surgical revision in 5 patients (2.6%) after 2.1 ± 1.9 years (range, 19 days to 4.1 years). Late deaths occurred in 5.9% (2/34) of patients with a BJV size of 12 to 14 mm versus 1.9% (3/159) in patients with a size of 16 to 22 mm (P = NS). An interventional procedure or surgical revision was required in 29.4% (10/34) of patients with a BJV size of 12 to 14 mm versus 3.1% (5/159) in patients with a size of 16 to 22 mm (P < .0005).
Conclusions:
After 10 years of experience with the BJV, this conduit has remained a reliable alternative to pulmonary homografts with respect to survival and freedom from conduit failure. However, the incidence was greater and the presentation of conduit failure was earlier in patients with a smaller size BJV conduit (12-14 mm).
Related Concept Videos
Hemodialysis II: Procedure and Complications
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Hemodialysis I: Introduction
Esophageal Varices-I: Introduction