Related Experiment Video
Updated: Jun 8, 2026

Analyzing Dendritic Morphology in Columns and Layers
Published on: March 23, 2017
Deconvolution of multiple images of the same object
Abstract:
Deconvolution of images of the same object from multiple sensors with different point spread functions as suggested by Berenstein [Proc. IEEE 78, 723 (1990); Stochastic and Neural Methods in Signal Processing, Image Processing, and Computer Vision, S. Chen, ed., Proc. Soc. Photo-Opt. Instrum. Eng. 1569, 35 (1991)], opens new opportunities in solving the image-deconvolution problem, which has challenged researchers for years. We attack this problem in a more realistic formulation than that used by Berenstein; it explicitly takes into account image sensor noise and the necessity for adaptive restoration with estimation of all required signal and noise parameters directly from the observed noisy signals. We show that arbitrary restoration accuracy can be achieved by the appropriate choice of the number of sensor channels and the signal-to-noise ratio in each channel. The results are then extended to the practically important situation when true images in different sensor channels are not identical.
More Related Videos
Related Concept Videos
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Super-resolution Fluorescence Microscopy
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Convolution Properties I
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output:
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Convolution: Math, Graphics, and Discrete Signals
To simplify the convolution integral, it is assumed that both the input signal and impulse response are zero for negative time values. The graphical convolution process...

