The relation between skin temperature increase and sensory block height in spinal anaesthesia using infrared

F G A M van Haren1, J J Driessen, L Kadic

  • 1Department of Anaesthesiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands. f.vanharen@anes.umcn.nl

Abstract

Related Concept Videos

Thermosensation01:43

Thermosensation

Peripheral thermosensation is the perception of external temperature. A change in temperature (on the surface of the skin and other tissues) is detected by a family of temperature-sensitive ion channels called Transient Receptor Potential, or TRP, receptors. These receptors are located on free nerve endings. Those detecting cold temperatures are closer to the surface of the skin than the nerve endings detecting warmth. These thermoTRP channels, while temperature selective, have relatively...
Assessing Body Temperature - Temporal Artery01:19

Assessing Body Temperature - Temporal Artery

Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.  
Step 3: Assess the patient's forehead...
Local Anesthetics: Clinical Application as Spinal Anesthesia01:11

Local Anesthetics: Clinical Application as Spinal Anesthesia

Spinal anesthetics are given during lower abdomen and limb surgeries to block sensory and motor neurons. They are administered in the mid to low lumbar regions, primarily acting on the cauda equina's nerve roots. The blockade level depends on the local anesthetic (LA) concentration. Usually, low LA concentrations are sufficient to block sensory fibers, while only high LA concentrations block motor fibers. Other factors like injection volume and speed, the patient's posture, and the drug...
Temperature Measurement Sites01:14

Temperature Measurement Sites

A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature01:13

Equipments Used to Measure Body Temperature

Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia01:16

Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia

Intravenous regional anesthesia or the Bier block technique is used to anesthetize a specific limb or extremity. It uses exsanguinated or blood-drained vessels to transport local anesthetics or LAs to the peripheral nerve trunks. Lidocaine without vasoconstrictors like epinephrine is most commonly used for this technique. Other drugs used are prilocaine, ropivacaine, and chloroprocaine. Bupivacaine is not recommended for this technique due to its high cardiac toxicity.
One of the advantages of...