Gastric Point of Care Ultrasound in Adults: Image Acquisition and Interpretation
Published on: September 22, 2023
Three-dimensional sonographic volume measurement of the fetal stomach
Toshiyuki Hata1, Hirokazu Tanaka, Junko Noguchi
1Department of Perinatology and Gynecology, Kagawa University School of Medicine, Miki, Kagawa, Japan. toshi28@med.kagawa-u.ac.jp
The objective of this study was to measure the fetal gastric volume using three-dimensional (3-D) ultrasound during pregnancy. Three-dimensional sonographic examinations were performed involving 35 pregnant women from 12 to 38 weeks of gestation. The fetal gastric volume was monitored every 5 min for a minimum of 40 min (40-60 min) in each woman. The rotational technique with Virtual Organ Computer-aided AnaLysis (VOCAL) was used to calculate the fetal gastric volume. Maximum and minimum gastric volumes were curvilinearly associated with the gestational age, respectively (R(2) = 0.611, p < 0.0001, and R(2) = 0.407, p < 0.0001, respectively). A curvilinear relationship was noted between the functional capacity (maximum volume - minimum volume) of the fetal stomach and gestational age (R(2) = 0.531, p < 0.0001). The maximum volume change [(maximum volume - minimum volume/maximum volume) × 100] did not change during pregnancy (mean and standard deviation, 64.1% ± 16.1%). However, gastric emptying cycles could not be determined in this study because of the short observation period and small number of subjects. Our findings suggest that the fetal gastric volume calculated by conventional two-dimensional ultrasound in previous investigations is approximately one-third of the maximum volume using 3-D ultrasound in the present study and that 3-D ultrasound is a superior means of evaluating the fetal gastric volume in utero. However, the data and their interpretation in the present study should be viewed with some degree of caution because of the small number of subjects. Further studies involving a larger sample size are needed to confirm these findings.
The objective of this study was to measure the fetal gastric volume using three-dimensional (3-D) ultrasound during pregnancy. Three-dimensional sonographic examinations were performed involving 35 pregnant women from 12 to 38 weeks of gestation. The fetal gastric volume was monitored every 5 min for a minimum of 40 min (40-60 min) in each woman. The rotational technique with Virtual Organ Computer-aided AnaLysis (VOCAL) was used to calculate the fetal gastric volume. Maximum and minimum gastric volumes were curvilinearly associated with the gestational age, respectively (R(2) = 0.611, p < 0.0001, and R(2) = 0.407, p < 0.0001, respectively). A curvilinear relationship was noted between the functional capacity (maximum volume - minimum volume) of the fetal stomach and gestational age (R(2) = 0.531, p < 0.0001). The maximum volume change [(maximum volume - minimum volume/maximum volume) × 100] did not change during pregnancy (mean and standard deviation, 64.1% ± 16.1%). However, gastric emptying cycles could not be determined in this study because of the short observation period and small number of subjects. Our findings suggest that the fetal gastric volume calculated by conventional two-dimensional ultrasound in previous investigations is approximately one-third of the maximum volume using 3-D ultrasound in the present study and that 3-D ultrasound is a superior means of evaluating the fetal gastric volume in utero. However, the data and their interpretation in the present study should be viewed with some degree of caution because of the small number of subjects. Further studies involving a larger sample size are needed to confirm these findings.
Related Concept Videos
Gross Anatomy of the Stomach
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...